Details
BUY K25A10K3 https://www.utsource.net/itm/p/8853194.html
Parameter | Symbol | Min | Typical | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | VIN | 4.5 | - | 26 | V | Operating input voltage range |
Output Voltage | VOUT | - | 10 | - | V | Fixed output voltage |
Output Current | IOUT | - | - | 3 | A | Maximum continuous output current |
Quiescent Current | IQ | - | 2.5 | 5 | mA | Current consumption at no load |
Dropout Voltage | VDROP | - | 0.5 | 1.2 | V | Voltage difference between input and output when output is under full load |
Line Regulation | - | - | 0.05 | 0.1 | % | Change in output voltage due to input voltage variation |
Load Regulation | - | - | 0.1 | 0.3 | % | Change in output voltage due to load current variation |
Ripple Rejection | - | - | 70 | 80 | dB | Ability to reject input ripple |
Operating Temperature | TOP | -40 | - | 125 | 掳C | Ambient temperature range |
Storage Temperature | TSTORAGE | -65 | - | 150 | 掳C | Temperature range for storage |
Instructions for Using K25A10K3
Power Supply Connection:
- Connect the positive terminal of the power supply to the input pin (VIN).
- Connect the negative terminal of the power supply to the ground pin (GND).
Output Connection:
- Connect the load to the output pin (VOUT) and the ground pin (GND).
Capacitors:
- Place a 10 渭F electrolytic capacitor between VIN and GND close to the regulator.
- Place a 10 渭F electrolytic capacitor between VOUT and GND close to the regulator to ensure stability.
Heat Dissipation:
- For high current applications, consider using a heatsink to dissipate heat generated by the regulator.
Overvoltage Protection:
- Ensure that the input voltage does not exceed the maximum rating to avoid damaging the regulator.
Reverse Polarity Protection:
- The regulator is not protected against reverse polarity. Use a diode in series with the input to prevent damage from reverse polarity.
Thermal Management:
- Monitor the temperature of the regulator during operation. If the temperature exceeds the operating range, reduce the load or improve cooling.
Layout Considerations:
- Keep the traces between the input and output capacitors and the regulator as short as possible to minimize inductance and improve stability.
Storage:
- Store the regulator in a dry environment within the specified storage temperature range to maintain its performance and reliability.
Handling:
- Handle the regulator with care to avoid mechanical stress or damage to the pins. Use appropriate ESD protection when handling to prevent static damage.
View more about K25A10K3 on main site