Details

BUY MAX485EPA MAX485 https://www.utsource.net/itm/p/8871909.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating range 3.0 5.5 V
Input High Voltage VIH 2.0 VCC V
Input Low Voltage VIL 0 0.8 V
Output High Voltage VOH IOL = -4mA VCC-0.4 VCC-0.1 V
Output Low Voltage VOL IOH = 4mA 0 0.2 V
Driver Enable Input Current IIN VIN = VCC/2 -1 0 1 渭A
Receiver Input Current IIH VIN = VCC-0.7V -1 0 1 渭A
Data Rate 20 Mbps
Propagation Delay tPD 350 ns
Power-on Reset Time tPOR 100 渭s

Instructions for MAX485EPA (MAX485)

  1. Power Supply:

    • Connect the VCC pin to a power supply within the operating range of 3.0V to 5.5V.
    • Ground the GND pin.
  2. Data Transmission:

    • To enable data transmission, connect the DE and RE pins to control logic levels.
    • For receiving data, set DE low and RE high.
    • For transmitting data, set both DE and RE low.
  3. RS-485 Communication:

    • Connect the A and B pins to the RS-485 differential bus.
    • Ensure termination resistors are used at each end of the bus for proper signal integrity.
  4. Signal Levels:

    • Ensure input signals meet the specified input voltage levels (VIH and VIL) for reliable operation.
  5. Data Rate:

    • The device supports data rates up to 20 Mbps; ensure that the communication protocol does not exceed this limit.
  6. Propagation Delay:

    • Account for propagation delay in timing calculations when designing your system.
  7. Power-on Reset:

    • Allow sufficient time for the power-on reset period (tPOR) before initiating any communication.
  8. Environmental Considerations:

    • Operate the device within recommended temperature ranges to ensure reliability and performance.
(For reference only)

View more about MAX485EPA MAX485 on main site