Details
BUY 25LC256T-I/SM https://www.utsource.net/itm/p/8970645.html
IC EEPROM 256K SPI 10MHZ 8SOIJ
Parameter | Description | Value |
---|---|---|
Device | Serial EEPROM | 25LC256T-I/SM |
Package | SOP-8 | - |
Operating Voltage (Vcc) | Supply Voltage Range | 2.5V to 5.5V |
Memory Size | Total Memory | 256 Kbits (32 Kbytes) |
Organization | Memory Organization | 32,768 x 8 bits |
Data Retention | Data Retention Time | 100 years |
Write Cycles | Endurance | 1,000,000 write cycles per byte |
Read Cycles | Read Cycles | Unlimited |
Page Write Size | Page Write Size | 32 bytes |
Serial Interface | Communication Protocol | SPI (Serial Peripheral Interface) |
Clock Frequency (fCLK) | Maximum Clock Frequency | 10 MHz |
Access Time (tACC) | Access Time | 55 ns (max) at Vcc = 5.5V, 25°C |
Standby Current (ISB) | Standby Current | 1 μA (max) at Vcc = 5.5V, 25°C |
Active Current (IACT) | Active Current | 2 mA (max) at fCLK = 10 MHz, Vcc = 5.5V, 25°C |
Write Time (tW) | Typical Write Time | 5 ms (max) for 32-byte page |
Operating Temperature (TA) | Operating Temperature Range | -40°C to +85°C |
Storage Temperature (TSTG) | Storage Temperature Range | -65°C to +150°C |
Package Marking | Package Marking | 25LC256T-I/SM |
Instructions
Power Supply:
- Connect Vcc to the power supply (2.5V to 5.5V).
- Connect GND to the ground.
Serial Interface:
- Connect the SPI pins as follows:
- SCK (Serial Clock): Connect to the master clock.
- MOSI (Master Out Slave In): Connect to the master data output.
- MISO (Master In Slave Out): Connect to the master data input.
- CS (Chip Select): Connect to the master chip select signal. Pull low to activate the device.
- Connect the SPI pins as follows:
Initialization:
- Ensure the device is powered and the CS pin is high to keep the device in standby mode.
- To communicate with the device, pull the CS pin low.
Reading Data:
- Send the READ command (0x03) followed by the 24-bit address of the memory location.
- The device will respond with the data from the specified address.
Writing Data:
- Send the WRITE ENABLE command (0x06) to enable writing.
- Send the WRITE command (0x02) followed by the 24-bit address and up to 32 bytes of data.
- Wait for the write cycle to complete (5 ms maximum).
Status Register:
- Use the READ STATUS REGISTER command (0x05) to read the status register.
- Use the WRITE STATUS REGISTER command (0x01) to write to the status register.
Protection:
- The device supports write protection using the status register. Set the WP bit to prevent accidental writes.
Power Down:
- When not in use, set the CS pin high to put the device into standby mode to reduce power consumption.
Handling:
- Handle the device with care to avoid static discharge, which can damage the component.
- Store the device in a dry, cool place within the specified storage temperature range.