TLP291(GB-TP,SE

TLP291(GB-TP,SE


Specifications
Details

BUY TLP291(GB-TP,SE https://www.utsource.net/itm/p/8973444.html

Parameter Symbol Conditions Min Typ Max Unit
Forward Voltage VF IF = 10 mA 1.2 1.5 V
Peak Forward Surge Current IFSM t = 10 ms 30 mA
Reverse Breakdown Voltage VBR IR = 5 mA 5 V
Reverse Current IR VR = 5 V 10 nA
Storage Temperature Tstg -40 110 掳C
Operating Temperature Topr -40 85 掳C

Instructions for TLP291 (GB-TP, SE)

  1. Handling Precautions:

    • Avoid exposing the device to excessive heat or moisture.
    • Handle with care to prevent physical damage.
  2. Mounting and Soldering:

    • Ensure that the soldering temperature does not exceed 260掳C for more than 10 seconds.
    • Allow adequate cooling time after soldering to avoid thermal shock.
  3. Electrical Connections:

    • Connect the anode (A) and cathode (K) correctly to avoid reverse polarity damage.
    • Use appropriate current limiting resistors when connecting to power supplies.
  4. Environmental Considerations:

    • Operate within the specified temperature range to ensure reliable performance.
    • Protect from environments with high levels of dust, corrosive gases, or other contaminants.
  5. Storage:

    • Store in a dry, cool place away from direct sunlight.
    • Follow anti-static precautions to protect against ESD damage.
  6. Testing:

    • Before installation, verify the device parameters using a multimeter or similar testing equipment.
    • Perform functional tests under operating conditions to ensure proper performance.
  7. Compliance:

    • Ensure compliance with relevant safety and regulatory standards for your application.
(For reference only)

View more about TLP291(GB-TP,SE on main site