TLP181(F)

TLP181(F)


Specifications
SKU
8973516
Details

BUY TLP181(F) https://www.utsource.net/itm/p/8973516.html
Optocoupler DC-IN 1-CH Transistor DC-OUT 4-Pin MFSOP T/R
Parameter Symbol Min Typ Max Unit Conditions
Forward Voltage VF - 1.2 1.5 V IF = 20 mA
Reverse Breakdown Voltage VBR 5 - 7 V IR = 10 渭A
Forward Current IF - - 30 mA VF = 1.5V
Output Current IC - - 10 mA VCE(sat) = 0.4V
Collector-Emitter Saturation Voltage VCE(sat) - 0.4 0.6 V IC = 10 mA, IF = 20 mA
Leakage Current ICEO - 100 500 nA VCE = 5V, TA = 25掳C
Isolation Voltage VI - - 500 Vrms 1 min, IOUT = 0.1 mA
Operating Temperature TOP -40 - 105 掳C -
Storage Temperature TS -55 - 125 掳C -

Instructions for Use:

  1. Mounting:

    • Ensure proper heat dissipation if high current is expected.
    • Avoid mechanical stress on the leads.
  2. Electrical Connections:

    • Connect the anode (A) to the positive supply.
    • Connect the cathode (K) to the input circuit.
    • Connect the collector (C) to the load.
    • Connect the emitter (E) to ground or the negative supply.
  3. Forward Current (IF):

    • Do not exceed the maximum forward current (30 mA) to prevent damage.
    • Use a current-limiting resistor if necessary.
  4. Reverse Voltage (VBR):

    • Ensure that the reverse voltage does not exceed the maximum rating (7 V) to avoid breakdown.
  5. Output Current (IC):

    • The output current should not exceed 10 mA to ensure reliable operation.
  6. Temperature Considerations:

    • Operate within the specified temperature range (-40掳C to 105掳C).
    • Store the device within the storage temperature range (-55掳C to 125掳C).
  7. Isolation Voltage:

    • Verify that the isolation voltage (500 Vrms) is sufficient for your application to ensure electrical safety.
  8. Leakage Current:

    • Account for the leakage current (up to 500 nA) in your design to avoid unexpected behavior.
  9. Handling:

    • Handle with care to avoid static discharge, which can damage the device.
    • Follow standard ESD (Electrostatic Discharge) precautions.
  10. Testing:

    • Test the device under typical operating conditions to ensure it meets the required specifications.
(For reference only)

View more about TLP181(F) on main site