TLP181(F)
Specifications
SKU
8973516
Details
BUY TLP181(F) https://www.utsource.net/itm/p/8973516.html
Optocoupler DC-IN 1-CH Transistor DC-OUT 4-Pin MFSOP T/R
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Forward Voltage | VF | - | 1.2 | 1.5 | V | IF = 20 mA |
| Reverse Breakdown Voltage | VBR | 5 | - | 7 | V | IR = 10 渭A |
| Forward Current | IF | - | - | 30 | mA | VF = 1.5V |
| Output Current | IC | - | - | 10 | mA | VCE(sat) = 0.4V |
| Collector-Emitter Saturation Voltage | VCE(sat) | - | 0.4 | 0.6 | V | IC = 10 mA, IF = 20 mA |
| Leakage Current | ICEO | - | 100 | 500 | nA | VCE = 5V, TA = 25掳C |
| Isolation Voltage | VI | - | - | 500 | Vrms | 1 min, IOUT = 0.1 mA |
| Operating Temperature | TOP | -40 | - | 105 | 掳C | - |
| Storage Temperature | TS | -55 | - | 125 | 掳C | - |
Instructions for Use:
Mounting:
- Ensure proper heat dissipation if high current is expected.
- Avoid mechanical stress on the leads.
Electrical Connections:
- Connect the anode (A) to the positive supply.
- Connect the cathode (K) to the input circuit.
- Connect the collector (C) to the load.
- Connect the emitter (E) to ground or the negative supply.
Forward Current (IF):
- Do not exceed the maximum forward current (30 mA) to prevent damage.
- Use a current-limiting resistor if necessary.
Reverse Voltage (VBR):
- Ensure that the reverse voltage does not exceed the maximum rating (7 V) to avoid breakdown.
Output Current (IC):
- The output current should not exceed 10 mA to ensure reliable operation.
Temperature Considerations:
- Operate within the specified temperature range (-40掳C to 105掳C).
- Store the device within the storage temperature range (-55掳C to 125掳C).
Isolation Voltage:
- Verify that the isolation voltage (500 Vrms) is sufficient for your application to ensure electrical safety.
Leakage Current:
- Account for the leakage current (up to 500 nA) in your design to avoid unexpected behavior.
Handling:
- Handle with care to avoid static discharge, which can damage the device.
- Follow standard ESD (Electrostatic Discharge) precautions.
Testing:
- Test the device under typical operating conditions to ensure it meets the required specifications.
View more about TLP181(F) on main site