Parameter Symbol Conditions Min Typ Max Unit
Forward Voltage VF IF = 5 mA - 1.2 1.6 V
Peak Forward Current IFP Pulse Width ≤ 1 ms - - 50 mA
Continuous Forward Current IF Tj = 25°C - - 30 mA
Reverse Voltage VR - - 5 V
Output Leakage Current IOL VDD = 5 V, Tj = 25°C - - 1 μA
Isolation Voltage VIORM Test Voltage 50 Hz/60 Hz 2.5 - 5.0 kVrms
Propagation Delay Time tPLH IF = 5 mA, VDD = 5 V - 8 12 μs
Storage Temperature Tstg -40 - 110 °C
Operating Temperature Topr -40 - 85 °C

Instructions for TLP160J (TPL.U.C.F)

  1. Handling Precautions:

    • Avoid exposing the device to excessive mechanical stress or moisture.
    • Handle with care to prevent damage to leads.
  2. Mounting Guidelines:

    • Ensure proper alignment of the device during mounting to avoid misalignment issues.
    • Use appropriate soldering techniques and temperatures to prevent thermal damage.
  3. Electrical Connections:

    • Connect the forward current (IF) within specified limits to ensure reliable operation.
    • Ensure reverse voltage (VR) does not exceed maximum ratings to prevent breakdown.
  4. Environmental Considerations:

    • Operate within the specified temperature ranges for both storage (Tstg) and operating conditions (Topr).
    • Protect against electrostatic discharge (ESD) during handling and installation.
  5. Testing and Validation:

    • Verify propagation delay time (tPLH) and other timing parameters meet application requirements.
    • Conduct periodic testing under operational conditions to ensure continued performance.
  6. Safety Measures:

    • Adhere to isolation voltage (VIORM) specifications to ensure safe operation in high-voltage environments.
    • Implement protective circuits as necessary to safeguard against transient voltages and currents.