Details
BUY 2SK2717 K2717 MOS 5A 900V TOSHIBA TO220F https://www.utsource.net/itm/p/9250337.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDSS | 900 | V | Maximum drain-source voltage | ||
Gate-Source Voltage | VGS | -15 | 15 | V | Maximum gate-source voltage | |
Continuous Drain Current | ID | 5 | A | Continuous drain current at Tc=25°C | ||
Pulse Drain Current | IDM | 30 | A | Pulse drain current (t=10ms) | ||
RDS(on) | RDS(on) | 0.7 | Ω | On-resistance at VGS=10V | ||
Input Capacitance | Ciss | 1600 | pF | Input capacitance | ||
Output Capacitance | Coss | 480 | pF | Output capacitance | ||
Reverse Transfer Capacitance | Crss | 400 | pF | Reverse transfer capacitance | ||
Total Device Dissipation | PD | 115 | W | Power dissipation at Tc=25°C | ||
Junction Temperature | TJ | 150 | °C | Maximum junction temperature |
Instructions for Use:
Mounting and Handling:
- Ensure proper heat sinking when mounting the device to maintain operational temperatures within specified limits.
- Handle with care to avoid damage to the leads and body.
Electrical Connections:
- Connect the drain, source, and gate terminals as per your circuit design ensuring correct polarity.
- Avoid exceeding the maximum ratings for VDSS, VGS, and ID to prevent device failure.
Thermal Management:
- Monitor the junction temperature (TJ) to ensure it does not exceed 150°C.
- Proper thermal management is crucial for reliable operation, especially under high power conditions.
Storage and Operating Conditions:
- Store in a dry environment away from direct sunlight and corrosive substances.
- Operate within the specified environmental conditions to ensure longevity and performance.
Testing and Verification:
- Before final assembly, verify all electrical parameters using appropriate test equipment.
- Conduct functional tests to ensure the device meets the application requirements.
Safety Precautions:
- Always follow safety guidelines when working with high voltage and current levels.
- Use protective equipment to prevent electrical shock or injury.
View more about 2SK2717 K2717 MOS 5A 900V TOSHIBA TO220F on main site