Parameter Symbol Min Typ Max Unit Description
Input Voltage VIN 2.0 5.0 5.5 V Supply voltage for the input side
Output Voltage VOUT - 3.3 5.0 V Supply voltage for the output side
Isolation Voltage VIOMAX - - 5000 V Maximum isolation voltage
Input Current IIN - 1.0 10.0 mA Supply current on the input side
Output Current IOUT - 1.0 10.0 mA Supply current on the output side
Propagation Delay Time tpd 0.8 1.2 1.6 渭s Time delay from input to output
Rise Time tr - 0.2 0.4 渭s Time for output to rise from 10% to 90%
Fall Time tf - 0.2 0.4 渭s Time for output to fall from 90% to 10%
Operating Temperature TA -40 - 105 掳C Ambient operating temperature range
Storage Temperature TSTG -55 - 150 掳C Storage temperature range
Relative Humidity RH - - 95 % Operating relative humidity (non-condensing)
Maximum Junction Temperature TJ - - 150 掳C Maximum junction temperature

Instructions for Use

  1. Supply Voltage:

    • Ensure that the input voltage (VIN) is within the specified range of 2.0V to 5.5V.
    • The output voltage (VOUT) should be set to either 3.3V or 5.0V as required.
  2. Isolation:

    • The device provides a maximum isolation voltage of 5000V, which ensures safe operation in high-voltage environments.
  3. Current Requirements:

    • The input current (IIN) and output current (IOUT) should not exceed 10.0mA to avoid damage to the device.
  4. Timing Parameters:

    • The propagation delay time (tpd) is typically between 0.8渭s and 1.6渭s, ensuring fast signal transmission.
    • The rise time (tr) and fall time (tf) are both typically around 0.2渭s to 0.4渭s, providing sharp transitions.
  5. Temperature and Environmental Conditions:

    • Operate the device within the ambient temperature range of -40掳C to 105掳C.
    • Store the device in an environment with a temperature range of -55掳C to 150掳C.
    • Maintain a relative humidity of up to 95% (non-condensing) during operation.
  6. Handling:

    • Handle the device with care to avoid static discharge, which can damage the internal components.
    • Follow standard ESD (Electrostatic Discharge) precautions when handling the device.
  7. Mounting:

    • Ensure proper mounting to a suitable PCB (Printed Circuit Board) with appropriate soldering techniques.
    • Verify that the device is securely mounted to prevent mechanical stress.

By adhering to these parameters and instructions, you can ensure reliable and efficient operation of the ACPL-K73L optocoupler.