ACPL-K73L
Specifications
SKU
9250669
Details
BUY ACPL-K73L https://www.utsource.net/itm/p/9250669.html
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 2.0 | 5.0 | 5.5 | V | Supply voltage for the input side |
| Output Voltage | VOUT | - | 3.3 | 5.0 | V | Supply voltage for the output side |
| Isolation Voltage | VIOMAX | - | - | 5000 | V | Maximum isolation voltage |
| Input Current | IIN | - | 1.0 | 10.0 | mA | Supply current on the input side |
| Output Current | IOUT | - | 1.0 | 10.0 | mA | Supply current on the output side |
| Propagation Delay Time | tpd | 0.8 | 1.2 | 1.6 | 渭s | Time delay from input to output |
| Rise Time | tr | - | 0.2 | 0.4 | 渭s | Time for output to rise from 10% to 90% |
| Fall Time | tf | - | 0.2 | 0.4 | 渭s | Time for output to fall from 90% to 10% |
| Operating Temperature | TA | -40 | - | 105 | 掳C | Ambient operating temperature range |
| Storage Temperature | TSTG | -55 | - | 150 | 掳C | Storage temperature range |
| Relative Humidity | RH | - | - | 95 | % | Operating relative humidity (non-condensing) |
| Maximum Junction Temperature | TJ | - | - | 150 | 掳C | Maximum junction temperature |
Instructions for Use
Supply Voltage:
- Ensure that the input voltage (VIN) is within the specified range of 2.0V to 5.5V.
- The output voltage (VOUT) should be set to either 3.3V or 5.0V as required.
Isolation:
- The device provides a maximum isolation voltage of 5000V, which ensures safe operation in high-voltage environments.
Current Requirements:
- The input current (IIN) and output current (IOUT) should not exceed 10.0mA to avoid damage to the device.
Timing Parameters:
- The propagation delay time (tpd) is typically between 0.8渭s and 1.6渭s, ensuring fast signal transmission.
- The rise time (tr) and fall time (tf) are both typically around 0.2渭s to 0.4渭s, providing sharp transitions.
Temperature and Environmental Conditions:
- Operate the device within the ambient temperature range of -40掳C to 105掳C.
- Store the device in an environment with a temperature range of -55掳C to 150掳C.
- Maintain a relative humidity of up to 95% (non-condensing) during operation.
Handling:
- Handle the device with care to avoid static discharge, which can damage the internal components.
- Follow standard ESD (Electrostatic Discharge) precautions when handling the device.
Mounting:
- Ensure proper mounting to a suitable PCB (Printed Circuit Board) with appropriate soldering techniques.
- Verify that the device is securely mounted to prevent mechanical stress.
By adhering to these parameters and instructions, you can ensure reliable and efficient operation of the ACPL-K73L optocoupler.
(For reference only)View more about ACPL-K73L on main site