| Parameter | Symbol | Min | Typ | Max | Unit | Conditions/Notes |
|---|---|---|---|---|---|---|
| Input Current (Forward) | IF | 10 | 20 | 50 | mA | VDD = 5V, TA = 25掳C |
| Input Voltage (Forward) | VF | 1.0 | 1.2 | 1.6 | V | IF = 20mA, TA = 25掳C |
| Input Capacitance | CIN | - | 10 | - | pF | VDD = 5V, f = 1MHz |
| Output Current (High) | IOH | - | - | -10 | mA | VDD = 5V, VOL = 0.4V, TA = 25掳C |
| Output Current (Low) | IOL | 10 | - | - | mA | VDD = 5V, VOH = 2.4V, TA = 25掳C |
| Output Voltage (High) | VOH | 2.4 | - | - | V | IOL = 10mA, VDD = 5V, TA = 25掳C |
| Output Voltage (Low) | VOL | - | - | 0.4 | V | IOH = -10mA, VDD = 5V, TA = 25掳C |
| Propagation Delay Time | tPD | 20 | 30 | 40 | ns | IF = 20mA, VDD = 5V, TA = 25掳C |
| Rise Time | tr | 8 | 12 | 16 | ns | IF = 20mA, VDD = 5V, TA = 25掳C |
| Fall Time | tf | 8 | 12 | 16 | ns | IF = 20mA, VDD = 5V, TA = 25掳C |
| Common-Mode Transient Immunity | CMTI | 25 | - | - | kV/渭s | VDD = 5V, TA = 25掳C |
| Isolation Voltage | VIORM | - | - | 5000 | Vrms | 1 minute, 50/60Hz, VDD = 5V, TA = 25掳C |
| Operating Temperature Range | TOPR | -40 | - | 105 | 掳C | - |
| Storage Temperature Range | TSTG | -65 | - | 150 | 掳C | - |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VDD) is within the specified range (4.75V to 5.25V).
- Connect the VDD pin to the positive power supply and GND to the ground.
Input Signal:
- Apply the input signal to the Anode (A) and Cathode (K) pins.
- The forward current (IF) should be within the recommended range (10mA to 50mA).
Output Signal:
- Connect the output pins (O1 and O2) to the load or next stage circuit.
- Ensure the output current (IOH and IOL) does not exceed the maximum ratings.
Propagation Delay:
- Measure the propagation delay (tPD) to ensure it meets the system timing requirements.
Common-Mode Transient Immunity (CMTI):
- Ensure the common-mode transient immunity (CMTI) is sufficient for the application environment to avoid false triggering.
Isolation:
- Verify that the isolation voltage (VIORM) is adequate for the intended application, especially in high-voltage environments.
Temperature Considerations:
- Operate the device within the specified temperature ranges to ensure reliable performance.
- Store the device in a temperature-controlled environment to prevent damage.
Handling:
- Handle the device with care to avoid static discharge and physical damage.
- Follow proper ESD protection guidelines during handling and installation.