HCPL-4503-500E

HCPL-4503-500E


Specifications
SKU
9255416
Details

BUY HCPL-4503-500E https://www.utsource.net/itm/p/9255416.html

Parameter Symbol Min Typ Max Unit Conditions/Notes
Input Current (Forward) IF 10 20 50 mA VDD = 5V, TA = 25掳C
Input Voltage (Forward) VF 1.0 1.2 1.6 V IF = 20mA, TA = 25掳C
Input Capacitance CIN - 10 - pF VDD = 5V, f = 1MHz
Output Current (High) IOH - - -10 mA VDD = 5V, VOL = 0.4V, TA = 25掳C
Output Current (Low) IOL 10 - - mA VDD = 5V, VOH = 2.4V, TA = 25掳C
Output Voltage (High) VOH 2.4 - - V IOL = 10mA, VDD = 5V, TA = 25掳C
Output Voltage (Low) VOL - - 0.4 V IOH = -10mA, VDD = 5V, TA = 25掳C
Propagation Delay Time tPD 20 30 40 ns IF = 20mA, VDD = 5V, TA = 25掳C
Rise Time tr 8 12 16 ns IF = 20mA, VDD = 5V, TA = 25掳C
Fall Time tf 8 12 16 ns IF = 20mA, VDD = 5V, TA = 25掳C
Common-Mode Transient Immunity CMTI 25 - - kV/渭s VDD = 5V, TA = 25掳C
Isolation Voltage VIORM - - 5000 Vrms 1 minute, 50/60Hz, VDD = 5V, TA = 25掳C
Operating Temperature Range TOPR -40 - 105 掳C -
Storage Temperature Range TSTG -65 - 150 掳C -

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the specified range (4.75V to 5.25V).
    • Connect the VDD pin to the positive power supply and GND to the ground.
  2. Input Signal:

    • Apply the input signal to the Anode (A) and Cathode (K) pins.
    • The forward current (IF) should be within the recommended range (10mA to 50mA).
  3. Output Signal:

    • Connect the output pins (O1 and O2) to the load or next stage circuit.
    • Ensure the output current (IOH and IOL) does not exceed the maximum ratings.
  4. Propagation Delay:

    • Measure the propagation delay (tPD) to ensure it meets the system timing requirements.
  5. Common-Mode Transient Immunity (CMTI):

    • Ensure the common-mode transient immunity (CMTI) is sufficient for the application environment to avoid false triggering.
  6. Isolation:

    • Verify that the isolation voltage (VIORM) is adequate for the intended application, especially in high-voltage environments.
  7. Temperature Considerations:

    • Operate the device within the specified temperature ranges to ensure reliable performance.
    • Store the device in a temperature-controlled environment to prevent damage.
  8. Handling:

    • Handle the device with care to avoid static discharge and physical damage.
    • Follow proper ESD protection guidelines during handling and installation.
(For reference only)

View more about HCPL-4503-500E on main site