HCPL-4514V-000E

HCPL-4514V-000E


Specifications
SKU
9255417
Details

BUY HCPL-4514V-000E https://www.utsource.net/itm/p/9255417.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 4.5 5.0 5.5 V Power supply voltage
Output High Level Voltage VOH - 4.5 VDD V Output high level voltage (at IO = 4 mA)
Output Low Level Voltage VOL - - 0.4 V Output low level voltage (at IO = 8 mA)
Output Leakage Current IOL - - 卤100 渭A Output leakage current
Input Current (Forward) IF 5 10 20 mA Forward current through the LED
Input Current (Reverse) IR - - 10 渭A Reverse current through the LED
Isolation Voltage VIORM - - 5000 Vrms Maximum isolation voltage (1 minute, 50/60 Hz)
Operating Temperature TOPR -40 - 105 掳C Operating temperature range
Storage Temperature TSTG -55 - 150 掳C Storage temperature range
Propagation Delay Time tPD - 100 300 ns Propagation delay time (input to output)
Pulse Width Distortion tPW - 20 50 ns Difference in propagation delay for rising and falling edges
Common Mode Transient Immunity CMTI - - 25 kV/渭s Common mode transient immunity

Instructions:

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the specified range of 4.5V to 5.5V.
    • Use a stable power supply to avoid fluctuations that could affect performance.
  2. Input LED:

    • The forward current (IF) through the input LED should be between 5mA and 20mA for reliable operation.
    • Avoid exceeding the maximum reverse current (IR) of 10渭A to prevent damage to the LED.
  3. Output:

    • The output high level voltage (VOH) should be at least 4.5V when the output current (IO) is 4mA.
    • The output low level voltage (VOL) should not exceed 0.4V when the output current (IO) is 8mA.
    • Ensure the output leakage current (IOL) does not exceed 卤100渭A to maintain proper logic levels.
  4. Isolation:

    • The device provides an isolation voltage (VIORM) of up to 5000Vrms for 1 minute at 50/60Hz. This ensures safety and protection against high voltages.
  5. Temperature:

    • Operate the device within the temperature range of -40掳C to 105掳C to ensure reliable performance.
    • Store the device in an environment with temperatures ranging from -55掳C to 150掳C.
  6. Timing:

    • The propagation delay time (tPD) should be between 100ns and 300ns.
    • The pulse width distortion (tPW) should be between 20ns and 50ns to ensure accurate signal transmission.
  7. Common Mode Transient Immunity (CMTI):

    • The device has a CMTI of 25kV/渭s, which helps in maintaining signal integrity in noisy environments.
  8. Handling:

    • Handle the device with care to avoid static discharge and physical damage.
    • Follow proper soldering techniques and use appropriate tools to ensure reliable connections.
  9. Mounting:

    • Mount the device on a PCB with adequate heat dissipation to prevent overheating.
    • Ensure all pins are securely connected and free from shorts or open circuits.
  10. Testing:

    • Test the device under typical operating conditions to verify its functionality.
    • Use a multimeter to check the output levels and ensure they meet the specified parameters.
(For reference only)

View more about HCPL-4514V-000E on main site