Details

BUY HCPL-7611-500E https://www.utsource.net/itm/p/9255427.html

Parameter Symbol Conditions Min Typ Max Unit
Input Forward Voltage V_F IF = 20 mA 1.2 1.6 V
Input Reverse Voltage V_R 5 V
Output Collector-Emitter Saturation Voltage V_CE(SAT) IC = 10 mA, IF = 20 mA 0.3 0.5 V
Output Collector Current I_C V_CE = 5V 5 7 mA
Propagation Delay Time tPLH IF = 20 mA, V_CC = 5V 0.4 1.2 渭s
Propagation Delay Time tPHL IF = 20 mA, V_CC = 5V 0.4 1.2 渭s
Common Mode Transient Immunity CMTI V_CM = 1 kV/渭s 25 kV/渭s

Instructions for HCPL-7611-500E

  1. Power Supply:

    • Ensure the power supply voltage (V_CC) is within the specified range to avoid damage to the device.
  2. Input Signal:

    • Apply a forward current (IF) of at least 20 mA to the input LED to ensure proper operation.
    • Do not exceed the maximum reverse voltage (V_R) on the input side.
  3. Output Side:

    • The collector-emitter saturation voltage (V_CE(SAT)) should be monitored to ensure it remains within the specified limits under load conditions.
    • The output collector current (I_C) must not exceed the maximum rating to prevent overheating or damage.
  4. Timing Considerations:

    • Account for the propagation delay times (tPLH and tPHL) in your circuit design to ensure accurate signal transmission.
  5. Common Mode Transient Immunity:

    • To maintain reliable operation in noisy environments, consider the common mode transient immunity (CMTI) specification when designing the surrounding circuitry.
  6. Handling Precautions:

    • Handle the device with care to avoid static damage.
    • Follow manufacturer guidelines for soldering temperature and duration to prevent thermal damage.
(For reference only)

View more about HCPL-7611-500E on main site