Details
BUY MAX1247BEPE https://www.utsource.net/itm/p/9262064.html
IC ADC 12BIT SAR 16DIP
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 4.5 | 5.5 | V | ||
| Operating Temperature | Toper | -40 | +85 | °C | ||
| Storage Temperature | Tstg | -65 | +150 | °C | ||
| Input Voltage Range | VIN | Differential | 0 | 2.048 | V | |
| Input Bias Current | IB | Differential | ±1 | ±3 | nA | |
| Common-Mode Input Range | VICR | 0 | 2.048 | V | ||
| Output Voltage Range | VOUT | 0 | VCC | V | ||
| Conversion Time | tCONV | 16-bit, 500 kSPS | 2.0 | μs | ||
| Power Consumption | IDD | 500 kSPS | 15 | mA | ||
| SNR (Signal-to-Noise Ratio) | SNR | 16-bit, 500 kSPS, 1 kHz input | 92 | dB | ||
| THD (Total Harmonic Distortion) | THD | 16-bit, 500 kSPS, 1 kHz input | -90 | dB |
Instructions for Using the MAX1247BEPE
Power Supply:
- Connect the VCC pin to a 4.5V to 5.5V power supply.
- Ensure the ground (GND) is properly connected to the system ground.
Input Signal:
- Connect the differential input signals to the IN+ and IN- pins.
- The input voltage range should be between 0V and 2.048V.
- Ensure the common-mode input range is within 0V to 2.048V.
Output Signal:
- The output is digital and can be read via the SPI interface.
- Connect the SCLK, MOSI, MISO, and CS pins to the corresponding SPI lines on your microcontroller or processor.
Configuration:
- Use the CS (Chip Select) pin to enable communication with the device.
- Set the conversion mode (single-shot or continuous) via the control register.
- Configure the resolution and other settings as needed.
Conversion:
- Start a conversion by sending the appropriate command over the SPI interface.
- Wait for the conversion time (2.0 μs at 500 kSPS) before reading the result.
- Read the 16-bit result from the MISO line.
Power Management:
- To reduce power consumption, set the device to a lower sampling rate or use the power-down mode when not in use.
- The device consumes approximately 15 mA at 500 kSPS.
Temperature Considerations:
- Operate the device within the temperature range of -40°C to +85°C.
- Store the device in the temperature range of -65°C to +150°C.
Electrostatic Discharge (ESD) Protection:
- Handle the device with ESD precautions to avoid damage.
- Use appropriate grounding and shielding techniques in your design.
By following these instructions, you can ensure optimal performance and reliability of the MAX1247BEPE in your application.
(For reference only)View more about MAX1247BEPE on main site