Details
BUY EE-SX1088 https://www.utsource.net/itm/p/9454688.html
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions/Notes |
|---|---|---|---|---|---|---|
| Operating Voltage | VCC | 4.5 | - | 5.5 | V | - |
| Operating Current | ICC | - | 3 | - | mA | Typical value at VCC = 5V |
| Output Type | - | - | - | - | NPN open collector | - |
| Maximum Load Current | IL | - | - | 50 | mA | Continuous |
| Maximum Output Voltage | VO | - | - | 30 | V | - |
| Detection Distance | S | 2 | 3 | 4 | mm | At VCC = 5V, Target: 1mm thick steel plate |
| Response Time | tR | - | 1 | - | ms | Turn-ON |
| Release Time | tF | - | 1 | - | ms | Turn-OFF |
| Ambient Temperature | TA | -40 | - | 85 | °C | Storage and operation |
| Storage Temperature | TSTG | -40 | - | 85 | °C | - |
| Humidity | H | - | - | 95 | % RH | Non-condensing |
Instructions for Use:
Power Supply:
- Connect the positive terminal of the power supply to the VCC pin.
- Connect the negative terminal of the power supply to the GND pin.
- Ensure the operating voltage is within the specified range (4.5V to 5.5V).
Output Connection:
- The output is an NPN open collector type.
- Connect the load between the output pin (OUT) and the positive supply (VCC).
- A pull-up resistor is required between the output pin and VCC. A typical value is 1kΩ to 10kΩ.
Mounting:
- Mount the sensor on a stable surface to ensure consistent detection.
- Avoid mounting in areas with high vibration or mechanical stress.
Target Detection:
- The sensor is designed to detect ferrous metal targets.
- The detection distance can vary based on the target material and thickness.
- For optimal performance, use a 1mm thick steel plate as a reference target.
Environmental Considerations:
- Operate the sensor within the specified temperature and humidity ranges.
- Protect the sensor from condensation and direct exposure to water.
Response and Release Times:
- The sensor has a typical response time of 1ms for both turn-ON and turn-OFF.
- These times may vary slightly depending on environmental conditions and load characteristics.
Handling and Installation:
- Handle the sensor with care to avoid damage to the sensitive components.
- Follow proper ESD (Electrostatic Discharge) precautions during installation and handling.
Troubleshooting:
- If the sensor does not operate correctly, check the power supply connections and ensure the load is properly connected.
- Verify that the target is within the specified detection range and material specifications.
For more detailed information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about EE-SX1088 on main site