TLP131GB-TPL.F

TLP131GB-TPL.F


Specifications
SKU
9506878
Details

BUY TLP131GB-TPL.F https://www.utsource.net/itm/p/9506878.html

Parameter Symbol Min Typ Max Unit Condition
Forward Voltage VF 1.0 1.2 1.4 V IF = 20 mA
Reverse Breakdown Voltage VBR -5 - -50 V IR = 1 μA
Forward Current IF - 20 50 mA VR = 0 V
Peak Forward Current IFP - - 100 mA Pulse Width ≤ 1 ms
Reverse Current IR - - 1 μA VR = -50 V
Output Collector-Emitter Saturation Voltage VCE(sat) 0.1 0.2 0.3 V IC = 5 mA, IF = 20 mA
Output Collector Current IC - 5 10 mA IF = 20 mA
Output Leakage Current IOL - - 10 nA VCE = 5 V, IF = 0
Isolation Voltage VIORM - - 5000 Vrms Test Condition: 1 minute
Operating Temperature TOPR -40 - 105 °C -
Storage Temperature TSTG -40 - 125 °C -

Instructions for Use:

  1. Forward Current (IF):

    • Ensure that the forward current does not exceed 50 mA continuously to avoid damaging the device.
    • For pulse applications, the peak forward current can be up to 100 mA with a pulse width of 1 ms or less.
  2. Reverse Voltage (VR):

    • The reverse voltage should not exceed 50 V to prevent breakdown.
    • Ensure that the reverse leakage current (IR) is kept below 1 μA at the maximum reverse voltage.
  3. Output Collector-Emitter Saturation Voltage (VCE(sat)):

    • The output collector-emitter saturation voltage should be monitored to ensure it remains within the specified range to maintain optimal performance.
  4. Output Collector Current (IC):

    • The output collector current should not exceed 10 mA to prevent overheating and potential damage to the device.
  5. Isolation Voltage (VIORM):

    • The isolation voltage is rated at 5000 Vrms for 1 minute. Ensure that this rating is not exceeded during operation to maintain safety and reliability.
  6. Temperature Considerations:

    • The operating temperature range is from -40°C to 105°C. Ensure that the device is used within this range to avoid thermal stress.
    • The storage temperature range is from -40°C to 125°C. Store the device in a suitable environment to prevent damage.
  7. Handling and Mounting:

    • Handle the device with care to avoid mechanical stress and electrostatic discharge (ESD).
    • Follow proper soldering procedures to ensure reliable connections without causing thermal damage.
  8. Testing:

    • Perform regular testing to ensure that all parameters remain within the specified limits.
    • Use appropriate test equipment and methods to avoid introducing errors or damage during testing.
  9. Compliance:

    • Ensure that the device complies with all relevant safety and regulatory standards for your application.

By following these guidelines, you can ensure the reliable and safe operation of the TLP131GB-TPL.F optocoupler.

(For reference only)

View more about TLP131GB-TPL.F on main site