TLP131GB-TPL.F
Specifications
SKU
9506878
Details
BUY TLP131GB-TPL.F https://www.utsource.net/itm/p/9506878.html
| Parameter | Symbol | Min | Typ | Max | Unit | Condition |
|---|---|---|---|---|---|---|
| Forward Voltage | VF | 1.0 | 1.2 | 1.4 | V | IF = 20 mA |
| Reverse Breakdown Voltage | VBR | -5 | - | -50 | V | IR = 1 μA |
| Forward Current | IF | - | 20 | 50 | mA | VR = 0 V |
| Peak Forward Current | IFP | - | - | 100 | mA | Pulse Width ≤ 1 ms |
| Reverse Current | IR | - | - | 1 | μA | VR = -50 V |
| Output Collector-Emitter Saturation Voltage | VCE(sat) | 0.1 | 0.2 | 0.3 | V | IC = 5 mA, IF = 20 mA |
| Output Collector Current | IC | - | 5 | 10 | mA | IF = 20 mA |
| Output Leakage Current | IOL | - | - | 10 | nA | VCE = 5 V, IF = 0 |
| Isolation Voltage | VIORM | - | - | 5000 | Vrms | Test Condition: 1 minute |
| Operating Temperature | TOPR | -40 | - | 105 | °C | - |
| Storage Temperature | TSTG | -40 | - | 125 | °C | - |
Instructions for Use:
Forward Current (IF):
- Ensure that the forward current does not exceed 50 mA continuously to avoid damaging the device.
- For pulse applications, the peak forward current can be up to 100 mA with a pulse width of 1 ms or less.
Reverse Voltage (VR):
- The reverse voltage should not exceed 50 V to prevent breakdown.
- Ensure that the reverse leakage current (IR) is kept below 1 μA at the maximum reverse voltage.
Output Collector-Emitter Saturation Voltage (VCE(sat)):
- The output collector-emitter saturation voltage should be monitored to ensure it remains within the specified range to maintain optimal performance.
Output Collector Current (IC):
- The output collector current should not exceed 10 mA to prevent overheating and potential damage to the device.
Isolation Voltage (VIORM):
- The isolation voltage is rated at 5000 Vrms for 1 minute. Ensure that this rating is not exceeded during operation to maintain safety and reliability.
Temperature Considerations:
- The operating temperature range is from -40°C to 105°C. Ensure that the device is used within this range to avoid thermal stress.
- The storage temperature range is from -40°C to 125°C. Store the device in a suitable environment to prevent damage.
Handling and Mounting:
- Handle the device with care to avoid mechanical stress and electrostatic discharge (ESD).
- Follow proper soldering procedures to ensure reliable connections without causing thermal damage.
Testing:
- Perform regular testing to ensure that all parameters remain within the specified limits.
- Use appropriate test equipment and methods to avoid introducing errors or damage during testing.
Compliance:
- Ensure that the device complies with all relevant safety and regulatory standards for your application.
By following these guidelines, you can ensure the reliable and safe operation of the TLP131GB-TPL.F optocoupler.