Details
BUY MP5010HN https://www.utsource.net/itm/p/9520840.html
new
| Parameter | Description | Value |
|---|---|---|
| Part Number | MP5010HN | - |
| Function | Step-Down (Buck) Converter | - |
| Input Voltage | Operating Range | 4.75V to 28V |
| Output Voltage | Adjustable Range | 0.8V to 26V |
| Output Current | Maximum Continuous Output Current | 3A |
| Switching Frequency | Fixed Switching Frequency | 650kHz |
| Quiescent Current | Typical Quiescent Current at No Load | 20μA |
| Efficiency | Maximum Efficiency | Up to 95% |
| Protection Features | Overcurrent Protection, Thermal Shutdown, Short-Circuit Protection | - |
| Package Type | SOT-23-6L | - |
| Operating Temperature | Junction Temperature Range | -40°C to 125°C |
| Storage Temperature | Storage Temperature Range | -65°C to 150°C |
Instructions for Use:
Circuit Design:
- Ensure that the input voltage is within the specified range (4.75V to 28V).
- Set the output voltage using external resistors according to the formula provided in the datasheet.
- Choose appropriate inductors and capacitors to match the switching frequency and desired output ripple.
PCB Layout:
- Place the MP5010HN close to the input capacitor to minimize noise.
- Use wide traces for power paths to reduce resistance and inductance.
- Ground planes should be large and solid to ensure good thermal performance.
Thermal Management:
- Ensure adequate airflow or heat sinking if operating at high currents or in high ambient temperatures.
- Monitor the junction temperature to avoid exceeding the maximum operating temperature.
Testing:
- Verify the output voltage and current under different load conditions.
- Check for stability by observing the output ripple and transient response.
- Test the protection features by inducing overcurrent and short-circuit conditions.
Storage:
- Store the MP5010HN in a dry environment to prevent moisture damage.
- Follow ESD (Electrostatic Discharge) precautions when handling the device.
View more about MP5010HN on main site