Details
BUY HCPL-034H-500E https://www.utsource.net/itm/p/9524097.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Forward Voltage | V_F | IF = 20 mA | 1.2 | 1.6 | V | |
| Peak Reverse Voltage | V_RR | 5 | V | |||
| Reverse Current | I_R | VR = 5V | 100 | 渭A | ||
| Output Collector-Emitter Breakdown Voltage | BVCBO | IO = 0, T_A = 25掳C | 70 | V | ||
| Output Collector Saturation Voltage | V_CE(SAT) | IC = 10 mA, IO = 5 mA | 0.3 | 0.5 | V | |
| Output Collector Leakage Current | I_CEO | VCE = 30V, T_A = 25掳C | 50 | nA | ||
| Propagation Delay Time | tPLH | IF = 20 mA, VCC = 5V | 0.5 | 1 | 1.5 | 渭s |
| Propagation Delay Time | tPHL | IF = 20 mA, VCC = 5V | 0.5 | 1 | 1.5 | 渭s |
| Pulse Width Distortion | tPWD | IF = 20 mA, VCC = 5V | -0.5 | 0 | 0.5 | 渭s |
| Common Mode Transient Immunity | CMTI | VCC = 5V, IF = 20 mA | 25 | kV/渭s |
Instructions for HCPL-034H-500E
Power Supply Requirements:
- Ensure that the supply voltage (V_CC) is within the specified range to avoid damage to the device.
Input Current Handling:
- The input forward current (I_F) should be maintained at the recommended level to ensure reliable operation and prevent overheating.
Output Circuit Protection:
- Protect the output circuit from excessive voltages by ensuring that the collector-emitter breakdown voltage (BVCBO) is not exceeded.
Temperature Considerations:
- Operate the device within the recommended temperature range to maintain performance specifications.
Propagation Delay:
- Account for propagation delay times in your circuit design to ensure accurate timing.
Mounting and Handling:
- Handle the device with care to avoid damage to the leads and internal components. Follow proper ESD precautions.
Storage Conditions:
- Store the device in a dry, cool environment to prevent degradation over time.
Common Mode Transient Immunity:
- Ensure that the common mode transient immunity (CMTI) requirements are met to prevent malfunctions due to rapid changes in voltage.
Testing and Verification:
- Perform initial testing under controlled conditions to verify that all parameters meet the specified values before integrating into a larger system.
View more about HCPL-034H-500E on main site