Details
BUY STK672-640A https://www.utsource.net/itm/p/9750074.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | Operating condition | 4.5 | 5.5 | V | |
| Output Current per Channel | IOC | Per channel | 100 | mA | ||
| Total Output Current | ITOT | All channels | 640 | mA | ||
| Standby Current | ISB | VDD = 5V | 2 | μA | ||
| Operating Temperature | TOPR | -40 | 85 | °C | ||
| Storage Temperature | TSTG | -55 | 150 | °C |
Instructions for STK672-640A:
Power Supply:
- Ensure the supply voltage (VDD) is within the range of 4.5V to 5.5V for optimal operation.
Current Handling:
- The device can provide up to 100mA per channel and a total of 640mA across all channels.
- Do not exceed the maximum output current to avoid damage or malfunction.
Standby Mode:
- In standby mode, the current consumption is typically 2μA at VDD = 5V, minimizing power usage when inactive.
Temperature Range:
- Operate the device within the temperature range of -40°C to +85°C for reliable performance.
- Store the device between -55°C and +150°C.
Installation:
- Ensure proper heat dissipation if operating near the upper limits of current or temperature.
- Follow manufacturer guidelines for PCB layout to ensure stability and efficiency.
Handling:
- Handle with care to prevent electrostatic discharge (ESD), which can damage sensitive components.
- Use appropriate ESD protection measures during installation and handling.
For detailed application-specific instructions and more comprehensive data, refer to the official datasheet provided by the manufacturer.
(For reference only)View more about STK672-640A on main site