CD4046BE
Specifications
SKU
11226755
Details
BUY CD4046BE https://www.utsource.net/itm/p/11226755.html
IC PHASE-LOCK LOOP MCPWR 16-DIP
Below is the parameter table and instructions for the CD4046BE Phase-Locked Loop (PLL) IC.
CD4046BE Parameter Table
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Supply Voltage | VCC | 5 | 10 | 15 | V | |
Input Voltage Range | VI | -0.5 | VCC + 0.5 | V | ||
Output Voltage High | VOH | 2.4 | 3.5 | VCC - 0.1 | V | IO = 10 mA |
Output Voltage Low | VOL | 0 | 0.4 | 0.7 | V | IO = 10 mA |
Power Dissipation | PTOT | 1000 | mW | TA = 25°C | ||
Operating Temperature | TA | -40 | 85 | °C | ||
Storage Temperature | TSTG | -65 | 150 | °C | ||
Input Capacitance | CI | 10 | 20 | pF | f = 1 MHz | |
Output Capacitance | CO | 5 | 15 | pF | f = 1 MHz | |
Phase Detector Type 1 Output Current | IPD1 | -10 | -1 | 10 | μA | VOUT = 0 V to VCC |
Phase Detector Type 2 Output Current | IPD2 | -10 | -1 | 10 | μA | VOUT = 0 V to VCC |
VCO Frequency Range | fVCO | 1 | 10 | 100 | kHz | RVCO = 10 kΩ, CVCO = 100 pF |
VCO Control Voltage Range | VCTRL | 0 | VCC | V |
CD4046BE Instructions
Supply Voltage:
- The CD4046BE operates with a supply voltage range of 5V to 15V. Ensure that the supply voltage is within this range to avoid damage to the IC.
Input Signals:
- The input signals should be within the range of -0.5V to VCC + 0.5V. Exceeding these limits can cause damage to the IC.
Output Signals:
- The output high level (VOH) is typically around 3.5V when the supply voltage is 10V, and the output low level (VOL) is typically around 0.4V. Ensure that the load current does not exceed 10mA to maintain these levels.
Power Dissipation:
- The maximum power dissipation is 1000mW at 25°C ambient temperature. Ensure adequate heat dissipation if operating at higher temperatures or with higher power consumption.
Temperature Range:
- The operating temperature range is from -40°C to 85°C. The storage temperature range is from -65°C to 150°C.
Capacitance:
- The input capacitance is typically 10pF, and the output capacitance is typically 5pF. These values can affect the performance of the PLL, especially at high frequencies.
Phase Detectors:
- The CD4046BE has two phase detectors:
- Type 1 (XOR Gate): Provides a pulse-width modulated output.
- Type 2 (Edge-Triggered): Provides a charge pump output.
- Choose the appropriate phase detector based on your application requirements.
- The CD4046BE has two phase detectors:
VCO (Voltage-Controlled Oscillator):
- The VCO frequency range is from 1kHz to 100kHz with typical values of RVCO = 10kΩ and CVCO = 100pF. Adjust these values to achieve the desired frequency range.
- The control voltage (VCTRL) should be within the range of 0V to VCC.
Layout Considerations:
- Keep the layout compact and minimize the length of high-frequency signal traces to reduce noise and parasitic effects.
- Use bypass capacitors (e.g., 0.1μF) close to the power pins to filter out noise.
Testing and Troubleshooting:
- Verify the supply voltage and input signals before testing the IC.
- Check the output signals with an oscilloscope to ensure they meet the expected levels.
- If the PLL is not locking, check the VCO frequency range and phase detector settings.
By following these instructions, you can effectively use the CD4046BE in your phase-locked loop applications.
(For reference only)View more about CD4046BE on main site