DS1337S+

DS1337S+

Category: IC ChipsDriver Ics

Specifications
SKU
11245522
Details

BUY DS1337S+ https://www.utsource.net/itm/p/11245522.html

Parameter Symbol Conditions Min Typ Max Unit
Operating Voltage VCC Continuous 2.3 - 5.5 V
Operating Current ICC Active, VCC = 3V - 400 - μA
Standby Current ISB VCC = 3V - 1 - μA
Frequency Accuracy Δf 25°C - 0 20 ppm
Temperature Range Toper Operating -40 - 85 °C
Square Wave Output fSQW - 1 - 8192 Hz
Output Drive Capability IOL VCC = 3V, fSQW = 1kHz - 4 - mA
Input Leakage Current IIH VCC = 5.5V - 1 - μA
Output Leakage Current IOL VCC = 0V - 1 - μA
Data Retention tDR VCC = 0V - 10 - Years

Instructions for Using DS1337S+

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 2.3V to 5.5V.
    • The device can operate with a wide range of supply voltages, but optimal performance is achieved at 3V.
  2. Clock Accuracy:

    • The frequency accuracy is ±20 ppm at 25°C. For applications requiring higher accuracy, consider using a temperature-compensated crystal oscillator (TCXO).
  3. Current Consumption:

    • The active current consumption is typically 400 μA at 3V.
    • The standby current is typically 1 μA at 3V, making it suitable for battery-powered applications.
  4. Temperature Range:

    • The device operates over a temperature range from -40°C to +85°C.
  5. Square Wave Output:

    • The square wave output frequency can be set to 1 Hz, 1.024 kHz, 4.096 kHz, or 8.192 kHz.
    • The output drive capability is up to 4 mA at 3V and 1 kHz.
  6. Input and Output Leakage:

    • The input leakage current should not exceed 1 μA at 5.5V.
    • The output leakage current should not exceed 1 μA at 0V.
  7. Data Retention:

    • The device retains data for up to 10 years when the power is off (VCC = 0V).
  8. Programming:

    • Use I2C communication to program and read the time and date registers.
    • The I2C address is determined by the A0, A1, and A2 pins. Refer to the datasheet for specific address configurations.
  9. Reset:

    • The device does not have a reset pin. To reset the device, cycle the power (VCC) or use the software reset command via I2C.
  10. Handling:

    • Handle the device with care to avoid static damage.
    • Follow proper ESD precautions when handling and soldering the device.

For more detailed information, refer to the official DS1337S+ datasheet provided by Maxim Integrated.

(For reference only)

View more about DS1337S+ on main site