Details
BUY IXGH48N60C3D1 https://www.utsource.net/itm/p/11246676.html
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDS | - | 600 | - | V | |
Gate-Source Voltage | VGS | -20 | - | 20 | V | |
Continuous Drain Current | ID | - | 48 | - | A | @ TC = 25掳C |
Pulse Drain Current | ID(p) | - | 192 | - | A | tp = 10 渭s, IGT = 10 A |
Total Power Dissipation | PTOT | - | 300 | - | W | @ TC = 25掳C |
Junction Temperature | TJ | - | - | 175 | 掳C | |
Storage Temperature | TSTG | -55 | - | 150 | 掳C | |
Thermal Resistance, Junction to Case | R胃JC | - | 0.38 | - | 掳C/W |
Instructions for Use:
Handling Precautions:
- Handle the IXGH48N60C3D1 with care to avoid damage to the pins and the die.
- Use proper ESD (Electrostatic Discharge) protection when handling the device.
Mounting:
- Ensure that the device is mounted on a heatsink or a PCB with adequate thermal management to keep the junction temperature within the specified limits.
- Use thermal paste or a thermal pad between the device and the heatsink to improve heat dissipation.
Biasing:
- Apply the gate-source voltage (VGS) carefully to avoid exceeding the maximum ratings.
- Ensure that the gate drive circuitry can provide sufficient current to charge and discharge the gate capacitance quickly for efficient switching.
Operation:
- Operate the device within the specified drain-source voltage (VDS) and continuous drain current (ID) limits.
- For pulse operation, ensure that the pulse duration and current do not exceed the specified pulse drain current (ID(p)).
Storage:
- Store the device in a dry, cool environment to prevent moisture absorption and degradation.
- Follow the recommended storage temperature range to ensure long-term reliability.
Testing:
- Use appropriate test equipment and procedures to verify the performance of the device.
- Refer to the datasheet for specific test conditions and procedures.
Safety:
- Ensure that all electrical connections are secure and insulated to prevent short circuits and electrical hazards.
- Follow all relevant safety standards and regulations when designing and operating circuits containing this device.
View more about IXGH48N60C3D1 on main site