AT45DB321E-MWHF-T

AT45DB321E-MWHF-T


Specifications
SKU
11249116
Details

BUY AT45DB321E-MWHF-T https://www.utsource.net/itm/p/11249116.html

Parameter Description Value
Device AT45DB321E-MWHF-T
Package Package Type TSOP-48
Operating Voltage (Vcc) Supply Voltage Range 2.7 V to 3.6 V
Memory Size Total Memory 32 Mbits (4 MBytes)
Page Size Page Size for Read/Write Operations 264 Bytes (256 data bytes + 8 spare bytes)
Sector Size Sector Size for Erase Operations 8 KBytes (64 pages)
Block Size Block Size for Erase Operations 64 KBytes (8 sectors)
Write Time Page Program Time 2.5 ms (max)
Erase Time Sector Erase Time 300 ms (max)
Block Erase Time Block Erase Time 2400 ms (max)
Data Retention Data Retention at 25°C 100 years
Endurance Write/Erase Cycles 100,000 cycles
Operating Temperature Industrial Temperature Range -40°C to +85°C
Storage Temperature Storage Temperature Range -65°C to +150°C
Standby Current Standby Current (Vcc = 3.0V) 1 μA (max)
Active Current Active Current (Vcc = 3.0V) 15 mA (max)
Read Current Read Current (Vcc = 3.0V) 5 mA (max)
Write Current Write Current (Vcc = 3.0V) 15 mA (max)
Interface Communication Interface SPI (Serial Peripheral Interface)
Clock Frequency Maximum Clock Frequency 66 MHz
Data Transfer Rate Maximum Data Transfer Rate 132 Mbit/s
Pin Configuration Pin Count 48 pins
Dimensions Package Dimensions 12.0 mm x 18.0 mm x 1.2 mm

Instructions for Use

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the range of 2.7 V to 3.6 V.
    • Connect the Vcc pin to the power supply and GND pin to ground.
  2. Communication:

    • Use the SPI interface to communicate with the device.
    • Connect the SPI pins (MISO, MOSI, SCK, and CS) to the corresponding pins on your microcontroller or controller.
  3. Initialization:

    • Before performing any read/write operations, initialize the device by selecting it (CS low) and sending the appropriate command sequence.
  4. Reading Data:

    • To read data, send the Read command (0x03) followed by the address of the first byte to be read.
    • The device will then output the data on the MISO line.
  5. Writing Data:

    • To write data, send the Write Enable command (0x06) to prepare the device for writing.
    • Send the Page Program command (0x02) followed by the address and data to be written.
    • Wait for the Write In Progress (WIP) bit to clear before initiating another write operation.
  6. Erasing Data:

    • To erase a sector or block, send the Write Enable command (0x06).
    • Send the Sector Erase command (0x20) or Block Erase command (0x52) followed by the address of the sector or block to be erased.
    • Wait for the WIP bit to clear before initiating another erase operation.
  7. Status Check:

    • To check the status of the device, send the Read Status Register command (0x05).
    • The device will return the status register value, which includes the WIP bit and other status information.
  8. Power Management:

    • To reduce power consumption, use the Deep Power Down mode by sending the Deep Power Down command (0xB9).
    • To exit Deep Power Down mode, send the Release from Deep Power Down command (0xAB).
  9. Handling:

    • Handle the device with care to avoid static discharge and physical damage.
    • Store the device in a dry, cool place when not in use.
  10. Environmental Considerations:

    • Operate the device within the specified temperature ranges to ensure reliable performance and longevity.
    • Follow proper disposal procedures for end-of-life devices to minimize environmental impact.
(For reference only)

View more about AT45DB321E-MWHF-T on main site