Details
BUY H11L1M https://www.utsource.net/itm/p/11250297.html
| Parameter | Description | Value |
|---|---|---|
| Device Type | Optocoupler | - |
| Input Device | Photodiode | - |
| Output Device | Phototransistor | - |
| Isolation Voltage (VIORM) | Maximum Repetitive Peak Isolation Voltage | 5300 Vrms |
| Forward Current (IF) | Maximum Forward Current | 60 mA |
| Reverse Voltage (VR) | Maximum Reverse Voltage | 5 V |
| Collector-Emitter Voltage (VCE) | Maximum Collector-Emitter Voltage | 70 V |
| Collector Current (IC) | Maximum Collector Current | 50 mA |
| Storage Temperature (TSTG) | Operating Temperature Range for Storage | -40°C to +105°C |
| Operating Temperature (TOPR) | Operating Temperature Range | -40°C to +105°C |
| CTR (Current Transfer Ratio) | Minimum to Maximum CTR | 20% to 400% |
| Response Time (tPLH, tPHL) | Propagation Delay Time | 5 μs (max) |
| Rise Time (tr) | Rise Time | 2 μs (max) |
| Fall Time (tf) | Fall Time | 2 μs (max) |
Instructions for Using H11L1M:
Mounting:
- Ensure that the device is mounted on a PCB with proper spacing to avoid short circuits.
- Use a socket if frequent replacement is expected.
Electrical Connections:
- Connect the photodiode side (input) to the control circuit.
- Connect the phototransistor side (output) to the load circuit.
- Ensure correct polarity for both input and output connections.
Power Supply:
- Apply the appropriate forward current (IF) to the photodiode, not exceeding 60 mA.
- Ensure the collector-emitter voltage (VCE) does not exceed 70 V.
Heat Management:
- The device can operate within a temperature range of -40°C to +105°C.
- If operating at high temperatures, consider thermal management techniques such as heat sinks.
Isolation:
- The H11L1M provides electrical isolation up to 5300 Vrms. Ensure that this isolation is maintained to prevent electrical hazards.
Signal Integrity:
- For optimal performance, keep the signal paths short and use appropriate shielding to minimize noise interference.
Testing:
- Before final assembly, test the device to ensure it meets the specified CTR and response times.
- Use a multimeter or oscilloscope to verify the correct operation of the optocoupler.
Storage:
- Store the device in a dry, cool place away from direct sunlight and sources of heat.
- Handle with care to avoid mechanical damage.
Safety:
- Always follow safety guidelines when handling and testing high-voltage components.
- Use appropriate personal protective equipment (PPE) when necessary.
View more about H11L1M on main site