Details
BUY MAX202CSE https://www.utsource.net/itm/p/11250586.html
IC TRANSCEIVER FULL 2/2 16SO
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Operating Voltage | Vcc | 4.75 | 5 | 5.25 | V | |
| Output Current (High) | Ioh | Vo = 2.4V | -16 | -10 | -4 | mA |
| Output Current (Low) | Iol | Vo = 2.4V | 4 | 10 | 16 | mA |
| Input Current | IIH | VI = 5V | 0 | 1 | 10 | μA |
| Input Current | IIL | VI = 0V | -10 | -1 | 0 | μA |
| Propagation Delay (Low to High) | tPLH | VI = 0V to VO = 2.4V | 15 | 30 | 50 | ns |
| Propagation Delay (High to Low) | tPHL | VI = 5V to VO = 2.4V | 15 | 30 | 50 | ns |
| Power Dissipation | PD | VI = 5V, VO = 2.4V | 125 | mW | ||
| Operating Temperature | Toper | -40 | 85 | °C |
Instructions for Using MAX202CSE
Power Supply:
- Ensure the supply voltage (Vcc) is within the range of 4.75V to 5.25V.
- Connect the Vcc pin to the positive terminal of your power source and GND to the ground.
Signal Levels:
- For a high output level (VOH), the output current (Ioh) should be between -16mA and -4mA.
- For a low output level (VOL), the output current (Iol) should be between 4mA and 16mA.
- The input current (IIH) when the input is high (VI = 5V) should be between 0μA and 10μA.
- The input current (IIL) when the input is low (VI = 0V) should be between -10μA and 0μA.
Propagation Delay:
- The propagation delay from low to high (tPLH) and from high to low (tPHL) should be within 15ns to 50ns.
Power Dissipation:
- The maximum power dissipation (PD) should not exceed 125mW.
Temperature Range:
- The device can operate within a temperature range of -40°C to 85°C.
Handling:
- Handle the device with care to avoid static damage.
- Use proper grounding and anti-static measures when handling the device.
Schematic Integration:
- Refer to the datasheet for detailed pin configurations and recommended layout practices.
- Ensure all connections are secure and meet the specified electrical parameters.
Testing:
- Before finalizing the design, test the device under various conditions to ensure it meets the required performance specifications.
Storage:
- Store the device in a dry, cool place to prevent moisture damage.
Compliance:
- Ensure that the device complies with all relevant safety and regulatory standards for your application.
View more about MAX202CSE on main site