IC TRANSCEIVER FULL 2/2 16SO
Parameter Symbol Conditions Min Typ Max Unit
Operating Voltage Vcc 4.75 5 5.25 V
Output Current (High) Ioh Vo = 2.4V -16 -10 -4 mA
Output Current (Low) Iol Vo = 2.4V 4 10 16 mA
Input Current IIH VI = 5V 0 1 10 μA
Input Current IIL VI = 0V -10 -1 0 μA
Propagation Delay (Low to High) tPLH VI = 0V to VO = 2.4V 15 30 50 ns
Propagation Delay (High to Low) tPHL VI = 5V to VO = 2.4V 15 30 50 ns
Power Dissipation PD VI = 5V, VO = 2.4V 125 mW
Operating Temperature Toper -40 85 °C

Instructions for Using MAX202CSE

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the range of 4.75V to 5.25V.
    • Connect the Vcc pin to the positive terminal of your power source and GND to the ground.
  2. Signal Levels:

    • For a high output level (VOH), the output current (Ioh) should be between -16mA and -4mA.
    • For a low output level (VOL), the output current (Iol) should be between 4mA and 16mA.
    • The input current (IIH) when the input is high (VI = 5V) should be between 0μA and 10μA.
    • The input current (IIL) when the input is low (VI = 0V) should be between -10μA and 0μA.
  3. Propagation Delay:

    • The propagation delay from low to high (tPLH) and from high to low (tPHL) should be within 15ns to 50ns.
  4. Power Dissipation:

    • The maximum power dissipation (PD) should not exceed 125mW.
  5. Temperature Range:

    • The device can operate within a temperature range of -40°C to 85°C.
  6. Handling:

    • Handle the device with care to avoid static damage.
    • Use proper grounding and anti-static measures when handling the device.
  7. Schematic Integration:

    • Refer to the datasheet for detailed pin configurations and recommended layout practices.
    • Ensure all connections are secure and meet the specified electrical parameters.
  8. Testing:

    • Before finalizing the design, test the device under various conditions to ensure it meets the required performance specifications.
  9. Storage:

    • Store the device in a dry, cool place to prevent moisture damage.
  10. Compliance:

    • Ensure that the device complies with all relevant safety and regulatory standards for your application.