| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 2.7 | - | 5.5 | V | Operating supply voltage range |
| Output Voltage | VOUT | - | 2.5 | - | V | Nominal output voltage |
| Line Regulation | - | - | 0.01 | - | %/V | Change in output voltage with respect to supply voltage |
| Load Regulation | - | - | 0.01 | - | %/mA | Change in output voltage with respect to load current |
| Temperature Coefficient | - | - | 5 | - | ppm/°C | Change in output voltage per degree Celsius |
| Initial Accuracy | - | - | 0.1 | - | % | Maximum deviation from nominal output voltage |
| Output Current | IOUT | - | 10 | - | mA | Maximum continuous output current |
| Quiescent Current | IQ | - | 30 | - | μA | Current consumed by the device |
| Dropout Voltage | VDROP | - | 1.0 | - | V | Minimum difference between input and output voltages |
| Operating Temperature | TOP | -40 | - | 125 | °C | Range of ambient temperatures for operation |
Instructions for Using REF02AP
Power Supply Connection:
- Connect the positive terminal of the power supply to the VCC pin.
- Connect the negative terminal (ground) to the GND pin.
Output Connection:
- Connect the load or the next stage of your circuit to the VOUT pin.
- Ensure that the load current does not exceed the maximum output current rating (10 mA).
Decoupling Capacitors:
- Place a 0.1 μF ceramic capacitor between VCC and GND as close to the device as possible to reduce noise and improve stability.
- Optionally, place a 10 μF tantalum capacitor between VOUT and GND to further stabilize the output voltage.
Thermal Management:
- Ensure adequate heat dissipation if operating at high temperatures or high output currents.
- The device can operate over a wide temperature range (-40°C to 125°C), but performance may degrade at extreme temperatures.
Initial Setup:
- Before connecting the load, verify the output voltage using a multimeter to ensure it is within the expected range (2.5 V ± 0.1%).
Storage and Handling:
- Store the device in a dry environment to prevent moisture damage.
- Handle the device with care to avoid static discharge, which can damage sensitive components.
By following these instructions, you can ensure optimal performance and reliability of the REF02AP voltage reference.