NTR4003NT1G MOSFET N-Channel 60V 30A SOT-223/SC-73/TO261-4 marking TR8 DC-DC converter
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Continuous Drain Current | ID | - | 3.0 | - | A | @ VGS = 10V, Ta = 25°C |
Peak Drain Current | ID(PK) | - | 4.5 | - | A | @ VGS = 10V, Pulse Width ≤ 300 μs, Duty Cycle ≤ 2% |
Gate-Source Voltage | VGS | -10 | - | 10 | V | |
Drain-Source Voltage | VDS | - | - | 30 | V | |
Gate-Source Leakage Current | IGSS | - | 1.0 | - | μA | @ VGS = ±10V, Ta = 25°C |
Drain-Source On-State Resistance | RDS(ON) | - | 0.015 | - | Ω | @ VGS = 10V, ID = 3A, Ta = 25°C |
Total Power Dissipation | PD | - | 40 | - | W | @ Ta = 25°C |
Junction Temperature | TJ | - | - | 150 | °C | |
Storage Temperature | TSTG | -65 | - | 150 | °C |
Instructions for Use:
Handling and Storage:
- Store the NTR4003NT1G in a dry, cool environment to prevent moisture damage.
- Handle with care to avoid static discharge, which can damage the device.
Mounting:
- Ensure proper heat sinking to manage the thermal resistance and maintain the junction temperature within safe limits.
- Use appropriate mounting hardware to secure the device firmly to the heatsink.
Electrical Connections:
- Connect the drain (D), source (S), and gate (G) terminals correctly to avoid damage.
- Use short leads to minimize parasitic inductance and capacitance.
Biasing:
- Apply the gate-source voltage (VGS) within the specified range to ensure reliable operation.
- Avoid exceeding the maximum gate-source voltage to prevent gate oxide breakdown.
Current Limiting:
- Ensure that the continuous drain current (ID) does not exceed 3.0A to prevent overheating and potential failure.
- For peak currents, do not exceed 4.5A for pulse widths ≤ 300 μs and duty cycles ≤ 2%.
Thermal Management:
- Monitor the junction temperature (TJ) to ensure it does not exceed 150°C.
- Use thermal paste or thermal interface materials to improve heat transfer from the device to the heatsink.
Testing:
- Test the device under controlled conditions to verify its performance and reliability.
- Use a curve tracer or similar equipment to measure the device characteristics accurately.
Safety:
- Follow all safety guidelines when handling high-voltage and high-current circuits.
- Ensure proper grounding and isolation to prevent electrical shock.