Details
BUY 2SK2653 https://www.utsource.net/itm/p/11301232.html
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Drain-Source Voltage | V(DS) | - | 100 | - | V | |
Gate-Source Voltage | V(GS) | -10 | 0 | 10 | V | |
Drain Current | I(D) | - | 10 | - | A | V(DS) = 100V, Tc = 25掳C |
Gate Threshold Voltage | V(GS(th)) | 2 | 4 | 6 | V | I(D) = 1mA, Tc = 25掳C |
Transconductance | gfs | 3 | 5 | 7 | S | V(DS) = 10V, I(D) = 1A |
Input Capacitance | Ciss | - | 800 | - | pF | f = 1MHz |
Output Capacitance | Coss | - | 200 | - | pF | f = 1MHz |
Reverse Transfer | Crss | - | 100 | - | pF | f = 1MHz |
Total Power Dissipation | Ptot | - | 100 | - | W | Ta = 25掳C |
Junction Temperature | Tj | -55 | - | 150 | 掳C | |
Storage Temperature | Tstg | -55 | - | 150 | 掳C |
Instructions for Use:
Handling Precautions:
- The 2SK2653 is sensitive to electrostatic discharge (ESD). Use proper ESD protection measures when handling the device.
- Avoid exceeding the maximum ratings specified in the table to prevent damage to the device.
Mounting:
- Ensure that the device is securely mounted to a heatsink if operating at high power levels to maintain the junction temperature within safe limits.
- Use thermal paste or a thermal pad between the device and the heatsink to improve heat dissipation.
Biasing:
- Apply the gate-source voltage (V(GS)) carefully to avoid exceeding the threshold voltage range. The typical V(GS) for operation should be within the specified range to ensure reliable operation.
- Ensure that the drain-source voltage (V(DS)) does not exceed the maximum rating of 100V to prevent breakdown.
Operation:
- Monitor the drain current (I(D)) to ensure it does not exceed the maximum rating of 10A. Excessive current can lead to overheating and potential failure.
- Keep the junction temperature (Tj) within the specified range by ensuring adequate cooling and avoiding prolonged operation at high power levels.
Storage:
- Store the device in a dry, cool place away from direct sunlight and sources of heat.
- Follow the storage temperature range (-55掳C to 150掳C) to ensure the device remains in good condition.
Testing:
- When testing the device, use appropriate test equipment and follow the recommended test conditions to obtain accurate results.
- Measure the input capacitance (Ciss), output capacitance (Coss), and reverse transfer capacitance (Crss) using a capacitance meter at the specified frequency (1MHz).
By following these guidelines, you can ensure the reliable and efficient operation of the 2SK2653.
(For reference only)View more about 2SK2653 on main site