Details
BUY 6R125P = IPW60R125CP https://www.utsource.net/itm/p/11301362.html
Parameter | Symbol | Value | Unit |
---|---|---|---|
Maximum Drain-Source Voltage | VDS(max) | 600 | V |
Maximum Continuous Drain Current | ID(max) | 48 | A |
Peak Pulse Drain Current (t=10渭s, Duty Cycle=1%) | Ipp | 300 | A |
Maximum Gate-Source Voltage | VGS(max) | 卤20 | V |
On-State Resistance at 25掳C, VGS=10V | RDS(on) | 0.125 | 惟 |
On-State Resistance at 150掳C, VGS=10V | RDS(on) | 0.187 | 惟 |
Total Power Dissipation (Tc=25掳C) | PTOT | 300 | W |
Junction Temperature Range | TJ | -55 to 175 | 掳C |
Storage Temperature Range | TSTG | -55 to 175 | 掳C |
Thermal Resistance, Junction to Case | R胃JC | 0.6 | 掳C/W |
Thermal Resistance, Junction to Ambient | R胃JA | 40 | 掳C/W |
Instructions for Use:
Handling and Storage:
- Store in a dry, cool place away from direct sunlight.
- Handle with care to avoid mechanical damage or static discharge.
Mounting:
- Ensure proper heat sinking to manage thermal resistance.
- Use appropriate mounting hardware to secure the device firmly.
Electrical Connections:
- Apply gate-source voltage (VGS) within the specified range to avoid damage.
- Ensure drain-source voltage (VDS) does not exceed the maximum rating.
- Keep continuous drain current (ID) within the rated limits.
Thermal Management:
- Monitor junction temperature (TJ) to ensure it stays within the operational range.
- Use thermal paste between the device and heatsink for better thermal conductivity.
Pulse Operation:
- For pulse applications, ensure peak pulse drain current (Ipp) is within the specified limit and duty cycle is considered.
Safety Precautions:
- Do not exceed the maximum ratings under any operating conditions.
- Use appropriate protective equipment when handling high voltages and currents.
Testing:
- Test the device under controlled conditions to verify performance before final integration into the circuit.
Documentation:
- Refer to the datasheet for detailed specifications and application notes.
- Consult with the manufacturer for specific application advice if needed.
View more about 6R125P = IPW60R125CP on main site