Parameter Symbol Min Typ Max Unit Notes
Continuous Drain Current ID - 44 50 A @ Tc = 25掳C, VGS = 10V
Pulse Drain Current IGM - 132 150 A @ Tc = 25掳C, VGS = 10V, t = 10 渭s
Maximum Drain-Source Voltage VDS 600 - - V
Gate-Source Voltage VGS -10 0 15 V
Power Dissipation PD - - 180 W @ Tc = 25掳C
Junction Temperature TJ -55 - 175 掳C
Storage Temperature Tstg -55 - 150 掳C
Thermal Resistance RthJC - 0.5 - 掳C/W Junction to Case
RthJA - - 3.5 - 掳C/W Junction to Ambient

Instructions for Use:

  1. Handling and Storage:

    • Store the device in a dry, cool place.
    • Handle with care to avoid static discharge and physical damage.
  2. Mounting:

    • Ensure proper heat sinking to manage power dissipation, especially during high current operations.
    • Use recommended mounting torque for screws to ensure good thermal contact.
  3. Electrical Connections:

    • Apply gate-source voltage (VGS) within the specified range to avoid damage.
    • Ensure drain-source voltage (VDS) does not exceed the maximum rating.
    • Use appropriate gate drive circuits to control switching times and reduce power losses.
  4. Thermal Management:

    • Monitor junction temperature (TJ) to stay within safe operating limits.
    • Use thermal paste or thermal interface materials to improve heat transfer from the device to the heatsink.
  5. Testing:

    • Perform initial testing at lower power levels to verify correct operation.
    • Use protective equipment and follow safety guidelines when handling high voltages and currents.
  6. Application Considerations:

    • The device is suitable for applications requiring high efficiency and low on-state resistance, such as motor control, power supplies, and industrial electronics.
    • Refer to the datasheet for detailed application notes and circuit diagrams.