Parameter Description Value
Part Number Unique identifier for the component BCR16PM-12LA
Type Component type Power Module
Input Voltage Range Range of input voltages the module can handle 8VDC to 16VDC
Output Voltage Nominal output voltage 12VDC
Output Current Maximum continuous output current 1.5A
Efficiency Typical efficiency at nominal load 90%
Operating Temperature Range of ambient temperatures where the module can operate -40掳C to +85掳C
Storage Temperature Range of temperatures for storage -55掳C to +125掳C
Protection Features Types of protection included Overvoltage, Overcurrent, Short Circuit, Thermal Shutdown
Size (LxWxH) Physical dimensions of the module 30mm x 20mm x 10mm
Weight Weight of the module 15g
Mounting Type Method of mounting the module Surface Mount
Compliance Standards and certifications CE, UL, RoHS

Instructions for Use:

  1. Installation:

    • Ensure the input voltage is within the specified range (8VDC to 16VDC).
    • Connect the input power to the designated input terminals.
    • Connect the load to the output terminals, ensuring the load does not exceed the maximum output current of 1.5A.
  2. Operation:

    • Turn on the power supply to the module.
    • Monitor the output voltage and current to ensure they are within the specified limits.
    • If the module is used in a high-temperature environment, ensure adequate ventilation to prevent overheating.
  3. Maintenance:

    • Regularly inspect the module for signs of wear or damage.
    • Clean the module with a soft, dry cloth to remove dust and debris.
    • Do not use solvents or abrasive materials that could damage the module.
  4. Troubleshooting:

    • No Output Voltage: Check input voltage and connections. Ensure the module is not short-circuited.
    • Overheating: Verify proper ventilation and operating temperature. Reduce load if necessary.
    • Output Voltage Fluctuations: Check for stable input voltage and ensure the load is within the rated capacity.
  5. Storage:

    • Store the module in a dry, cool place within the storage temperature range (-55掳C to +125掳C).
    • Avoid exposure to extreme humidity and direct sunlight.
  6. Safety Precautions:

    • Do not exceed the maximum input voltage or output current ratings.
    • Handle the module with care to avoid physical damage.
    • Follow all local electrical codes and regulations when installing and using the module.
(For reference only)