KGF25N120KDA-U/P

KGF25N120KDA-U/P

Category: Transistors

Specifications
SKU
11530899
Details

BUY KGF25N120KDA-U/P https://www.utsource.net/itm/p/11530899.html

Parameter Symbol Min Typ Max Unit Notes
Breakdown Voltage BVdss - - 1200 V
Continuous Drain Current Id - 25 - A @ Tc = 25掳C
Pulse Drain Current Ipp - 100 - A @ Tc = 25掳C, t = 10 渭s, Duty Cycle = 1%
Gate-Source Voltage Vgs -15 - 15 V
Input Capacitance Ciss - 3600 - pF @ Vds = 600 V, f = 1 MHz
Output Capacitance Coss - 280 - pF @ Vds = 600 V, f = 1 MHz
Reverse Transfer Capacitance Crss - 800 - pF @ Vds = 600 V, f = 1 MHz
Total Gate Charge Qg - 115 - nC @ Vds = 600 V, Id = 10 A
On-State Resistance Rds(on) - 1.7 - @ Vgs = 10 V, Id = 25 A, Tc = 25掳C
Turn-On Delay Time td(on) - 45 - ns @ Vds = 600 V, Id = 10 A, Vgs = 10 V
Rise Time tr - 50 - ns @ Vds = 600 V, Id = 10 A, Vgs = 10 V
Turn-Off Delay Time td(off) - 50 - ns @ Vds = 600 V, Id = 10 A, Vgs = 10 V
Fall Time tf - 45 - ns @ Vds = 600 V, Id = 10 A, Vgs = 10 V
Junction Temperature Tj -55 - 150 掳C
Storage Temperature Tstg -55 - 150 掳C

Instructions for Use:

  1. Mounting and Handling:

    • Ensure proper heat sinking to maintain the junction temperature within the specified range.
    • Handle the device with care to avoid mechanical damage and electrostatic discharge (ESD).
  2. Biasing and Operation:

    • Apply the gate-source voltage (Vgs) within the specified limits to prevent gate oxide breakdown.
    • Ensure the drain current (Id) does not exceed the continuous or pulse ratings to avoid overheating and potential failure.
  3. Thermal Management:

    • Use appropriate thermal management techniques such as heatsinks and thermal paste to ensure the junction temperature remains below 150掳C.
    • Monitor the temperature during operation and ensure adequate cooling.
  4. Storage:

    • Store the device in a dry, cool environment to prevent moisture absorption and degradation.
    • Keep the device in its original packaging until ready for use to protect against ESD.
  5. Testing and Troubleshooting:

    • Test the device under controlled conditions to ensure it meets the specified parameters.
    • If the device fails to meet specifications, check for proper biasing, thermal management, and environmental conditions.
  6. Safety:

    • Always follow safety guidelines when handling high-voltage and high-current circuits.
    • Use appropriate personal protective equipment (PPE) and follow all relevant safety standards.
(For reference only)

View more about KGF25N120KDA-U/P on main site