Parameter Symbol Conditions Min Typ Max Unit
Input Forward Voltage VIF IF=10mA 1.2 1.5 V
Input Peak Reverse Voltage VIRM 5 V
Input Current IF TA=25掳C 15 30 50 mA
Isolation Voltage VIORM 1min, 50/60Hz 4000 Vrms
Zero Cross Range VZC -50 +50 V
Output Turn-On Time tr IT=1A 8 12 渭s
Output Turn-Off Time tf IT=1A 8 12 渭s
Repetitive Peak Off-State Voltage VDRM TJ=25掳C 600 V
RMS On-State Current IT(RMS) TC=70掳C, 1 cycle 100 mA

Instructions for MOC3082M:

  1. Mounting and Handling:

    • Handle the device carefully to avoid damage.
    • Ensure proper mounting on a PCB with adequate clearance.
  2. Input Circuit:

    • Connect the input side (pins 1 and 2) to your control circuit ensuring the current does not exceed the maximum specified.
    • Use appropriate resistors to limit the current through the LED.
  3. Output Circuit:

    • Connect the output side (pins 4 and 6) to the load you wish to control.
    • Ensure that the load voltage does not exceed the repetitive peak off-state voltage.
  4. Zero Cross Detection:

    • The MOC3082M includes zero-cross detection which helps in reducing EMI by switching at zero crossing points of the AC waveform.
  5. Isolation:

    • The device provides electrical isolation between input and output circuits up to 4000Vrms for 1 minute.
  6. Operating Temperature:

    • Ensure that the operating temperature is within the specified range to prevent overheating and potential failure.
  7. Safety Precautions:

    • Always use appropriate safety measures when handling high voltages.
    • Ensure the device is properly insulated and installed according to local electrical codes and standards.