TLP112A(TPL,F)

TLP112A(TPL,F)


Specifications
SKU
11545437
Details

BUY TLP112A(TPL,F) https://www.utsource.net/itm/p/11545437.html

Parameter Symbol Min Typ Max Unit Conditions
Forward Voltage VF - 1.2 1.6 V IF = 20 mA, TA = 25°C
Reverse Breakdown Voltage VBR 5 - 7 V IR = 5 mA
Output Collector-Emitter Voltage VCEO - - 30 V IC = 50 mA, TA = 25°C
Output Collector Current IC - - 50 mA VCEO = 30 V, TA = 25°C
Input Current IF - 20 - mA VF = 1.4 V, TA = 25°C
Current Transfer Ratio CTR 100 - 500 % IF = 20 mA, IC = 50 mA, TA = 25°C
Rise Time tr - 0.2 - μs IF = 20 mA, RL = 100 Ω, VCC = 5 V, CL = 100 pF
Fall Time tf - 0.2 - μs IF = 20 mA, RL = 100 Ω, VCC = 5 V, CL = 100 pF
Storage Temperature TSTG -40 - 110 °C -
Operating Temperature TA -40 - 100 °C -

Instructions for Use:

  1. Mounting:

    • Ensure that the TLP112A is mounted on a suitable PCB with proper spacing to avoid thermal issues.
    • Use appropriate soldering techniques to ensure good electrical and mechanical connections.
  2. Power Supply:

    • The input forward voltage (VF) should be within the specified range to ensure reliable operation.
    • The output collector-emitter voltage (VCEO) must not exceed 30 V to prevent damage to the device.
  3. Current Handling:

    • The input current (IF) should be set to 20 mA for optimal performance.
    • The output collector current (IC) should not exceed 50 mA to avoid overheating and potential failure.
  4. Temperature Considerations:

    • The operating temperature (TA) should be kept between -40°C and 100°C to ensure stable performance.
    • The storage temperature (TSTG) should be maintained between -40°C and 110°C to prevent degradation.
  5. Timing Parameters:

    • The rise time (tr) and fall time (tf) are critical for high-speed applications. Ensure that the load resistance (RL) and capacitance (CL) are within the recommended values to achieve the specified timing characteristics.
  6. Electrical Isolation:

    • The TLP112A provides electrical isolation between the input and output circuits, which is crucial for protecting sensitive components from high-voltage transients.
  7. Testing:

    • Before final assembly, test the device under typical operating conditions to verify its performance and reliability.
  8. Handling:

    • Handle the TLP112A with care to avoid static discharge, which can damage the internal components.
    • Use ESD-protected tools and work surfaces when handling the device.