TLP127(TPL,U,F)

TLP127(TPL,U,F)


Specifications
SKU
11545443
Details

BUY TLP127(TPL,U,F) https://www.utsource.net/itm/p/11545443.html

Parameter Symbol Min Typ Max Unit Conditions
Forward Voltage VF - 1.2 1.5 V IF = 20 mA
Reverse Voltage VRRM - - 5 V
Peak Forward Current IF(surge) - - 100 mA tp = 10 ms
Continuous Forward Current IF - - 20 mA TA = 25掳C
Output Current (Max) IC - - 30 mA VCE(sat) = 0.5 V
Collector-Emitter Saturation Voltage VCE(sat) - 0.5 0.7 V IC = 10 mA, IF = 5 mA
Turn-On Time ton - 1 3 渭s IF = 5 mA, IC = 10 mA
Turn-Off Time toff - 1 3 渭s IF = 5 mA, IC = 10 mA
Storage Temperature Range TSTG -40 - 100 掳C
Operating Temperature Range TA -40 - 85 掳C

Instructions for Use:

  1. Forward Voltage (VF):

    • Ensure that the forward voltage across the device does not exceed 1.5 V when the forward current (IF) is 20 mA.
  2. Reverse Voltage (VRRM):

    • The maximum reverse voltage that the device can withstand is 5 V.
  3. Peak Forward Current (IF(surge)):

    • The peak forward current should not exceed 100 mA for a pulse duration of 10 ms.
  4. Continuous Forward Current (IF):

    • The continuous forward current should not exceed 20 mA at an ambient temperature of 25掳C.
  5. Output Current (IC):

    • The maximum output current the device can handle is 30 mA with a collector-emitter saturation voltage (VCE(sat)) of 0.5 V.
  6. Collector-Emitter Saturation Voltage (VCE(sat)):

    • Ensure that the collector-emitter saturation voltage does not exceed 0.7 V when the collector current (IC) is 10 mA and the forward current (IF) is 5 mA.
  7. Turn-On Time (ton):

    • The turn-on time of the device is typically 1 渭s and should not exceed 3 渭s under standard conditions (IF = 5 mA, IC = 10 mA).
  8. Turn-Off Time (toff):

    • The turn-off time of the device is typically 1 渭s and should not exceed 3 渭s under standard conditions (IF = 5 mA, IC = 10 mA).
  9. Storage Temperature Range (TSTG):

    • Store the device in an environment where the temperature ranges from -40掳C to 100掳C.
  10. Operating Temperature Range (TA):

    • The device should operate within an ambient temperature range of -40掳C to 85掳C.

Additional Notes:

  • Always ensure that the device is used within its specified operating conditions to avoid damage.
  • Proper heat sinking may be required for applications where the device is operated near its maximum ratings.
  • Refer to the datasheet for more detailed information and specific application notes.
(For reference only)

View more about TLP127(TPL,U,F) on main site