TLP627(F)

TLP627(F)


Specifications
SKU
11545474
Details

BUY TLP627(F) https://www.utsource.net/itm/p/11545474.html

Parameter Symbol Min Typ Max Unit Conditions
Forward Voltage VF - 1.2 1.6 V IF = 20 mA, TA = 25掳C
Reverse Breakdown Voltage VBR 5 - 8 V IR = 1 mA, TA = 25掳C
Output Voltage VO - 0.4 0.6 V IO = 5 mA, TA = 25掳C
Output Current IO - 5 10 mA VO = 5 V, TA = 25掳C
Isolation Voltage VI - - 3750 Vrms 1 minute, 50/60 Hz, TA = 25掳C
Storage Temperature TSTG -40 - 105 掳C -
Operating Temperature TA -40 - 85 掳C -

Instructions for Use

  1. Mounting:

    • Ensure the TLP627(F) is mounted on a suitable PCB with appropriate soldering.
    • Avoid excessive heat during soldering to prevent damage to the device.
  2. Electrical Connections:

    • Connect the input side (anode and cathode) to the control circuit.
    • Connect the output side (collector and emitter) to the load or next stage of the circuit.
  3. Forward Voltage (VF):

    • The forward voltage should be within the specified range to ensure proper operation.
    • Exceeding the maximum forward voltage can lead to device failure.
  4. Reverse Breakdown Voltage (VBR):

    • Ensure the reverse voltage across the input does not exceed the breakdown voltage to avoid damage.
  5. Output Voltage (VO):

    • The output voltage should be monitored to ensure it remains within the specified range for reliable operation.
  6. Output Current (IO):

    • The output current should not exceed the maximum rating to prevent overheating and potential failure.
  7. Isolation Voltage (VI):

    • The isolation voltage must be maintained to ensure electrical safety and prevent short circuits between the input and output sides.
  8. Temperature Considerations:

    • Operate the device within the specified storage and operating temperature ranges to ensure reliability and longevity.
    • Avoid exposing the device to temperatures outside these ranges, as it can lead to performance degradation or failure.
  9. Handling:

    • Handle the TLP627(F) with care to avoid mechanical damage.
    • Use appropriate ESD (Electrostatic Discharge) precautions to prevent damage from static electricity.
  10. Testing:

    • Before final assembly, test the device to ensure it meets the specified parameters.
    • Use a multimeter or other appropriate testing equipment to verify the forward and reverse voltages, output voltage, and output current.
(For reference only)