Details
BUY IRG7PH42UD-EP https://www.utsource.net/itm/p/11546278.html
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Input Voltage | VIN | 8 | - | 20 | V | |
Output Voltage | VOUT | - | 5 | - | V | |
Continuous Output Current | IOUT | - | 42 | - | A | |
Peak Output Current | IOUT(PK) | - | 70 | - | A | |
Switching Frequency | fSW | - | 500 | - | kHz | |
Efficiency | 畏 | - | 95 | - | % | |
Operating Temperature | TOP | -40 | - | 125 | 掳C | |
Storage Temperature | TSTG | -65 | - | 150 | 掳C | |
Junction Temperature | TJ | - | - | 175 | 掳C | |
Thermal Resistance (J-C) | R胃JC | - | 0.5 | - | 掳C/W |
Instructions for Use
Power Supply:
- Ensure the input voltage is within the specified range (8V to 20V).
- Connect the input voltage to the designated pins on the device.
Output Configuration:
- The output voltage is fixed at 5V.
- Connect the load to the output terminals ensuring the current does not exceed the continuous output current rating of 42A.
Thermal Management:
- Place the device on a heatsink or use a thermal pad to ensure efficient heat dissipation.
- Monitor the junction temperature to ensure it does not exceed 175掳C.
Operating Conditions:
- Operate the device within the specified temperature range (-40掳C to 125掳C).
- Store the device in a dry environment within the storage temperature range (-65掳C to 150掳C).
Switching Frequency:
- The device operates at a switching frequency of 500kHz. Ensure the external components (inductors, capacitors) are compatible with this frequency.
Efficiency:
- The typical efficiency is 95%. Monitor the power consumption and heat dissipation to ensure optimal performance.
Protection Features:
- The device includes overcurrent protection and thermal shutdown features to prevent damage under fault conditions.
Handling Precautions:
- Handle the device with care to avoid mechanical stress and electrostatic discharge (ESD).
- Follow standard ESD handling procedures when working with the device.
Mounting:
- Solder the device to the PCB following the recommended soldering profile.
- Ensure all connections are secure and free from shorts or open circuits.
Testing:
- After assembly, test the device under normal operating conditions to verify functionality.
- Perform periodic maintenance checks to ensure continued reliable operation.
View more about IRG7PH42UD-EP on main site