Parameter Symbol Min Typ Max Unit Notes
Input Voltage VIN 8 - 20 V
Output Voltage VOUT - 5 - V
Continuous Output Current IOUT - 42 - A
Peak Output Current IOUT(PK) - 70 - A
Switching Frequency fSW - 500 - kHz
Efficiency - 95 - %
Operating Temperature TOP -40 - 125 掳C
Storage Temperature TSTG -65 - 150 掳C
Junction Temperature TJ - - 175 掳C
Thermal Resistance (J-C) R胃JC - 0.5 - 掳C/W

Instructions for Use

  1. Power Supply:

    • Ensure the input voltage is within the specified range (8V to 20V).
    • Connect the input voltage to the designated pins on the device.
  2. Output Configuration:

    • The output voltage is fixed at 5V.
    • Connect the load to the output terminals ensuring the current does not exceed the continuous output current rating of 42A.
  3. Thermal Management:

    • Place the device on a heatsink or use a thermal pad to ensure efficient heat dissipation.
    • Monitor the junction temperature to ensure it does not exceed 175掳C.
  4. Operating Conditions:

    • Operate the device within the specified temperature range (-40掳C to 125掳C).
    • Store the device in a dry environment within the storage temperature range (-65掳C to 150掳C).
  5. Switching Frequency:

    • The device operates at a switching frequency of 500kHz. Ensure the external components (inductors, capacitors) are compatible with this frequency.
  6. Efficiency:

    • The typical efficiency is 95%. Monitor the power consumption and heat dissipation to ensure optimal performance.
  7. Protection Features:

    • The device includes overcurrent protection and thermal shutdown features to prevent damage under fault conditions.
  8. Handling Precautions:

    • Handle the device with care to avoid mechanical stress and electrostatic discharge (ESD).
    • Follow standard ESD handling procedures when working with the device.
  9. Mounting:

    • Solder the device to the PCB following the recommended soldering profile.
    • Ensure all connections are secure and free from shorts or open circuits.
  10. Testing:

    • After assembly, test the device under normal operating conditions to verify functionality.
    • Perform periodic maintenance checks to ensure continued reliable operation.