CD4046B

CD4046B

Category: IC Chips

Specifications
SKU
11547541
Details

BUY CD4046B https://www.utsource.net/itm/p/11547541.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 3.0 5.0 15.0 V
Supply Current (Quiescent) ICC fin = 10 kHz, VCC = 5V - 2.5 5.0 mA
Phase Detector Output Voltage VPD VCC = 5V - - 5.0 V
VCO Frequency Range fVCO VCC = 5V, Vctl = 0 to VCC 10 100 1000 kHz
VCO Control Voltage Vctl - 0 - VCC V
Input Voltage (Phase Detector) Vin - 0 - VCC V
Output Voltage (Phase Detector) Vout - 0 - VCC V
Output Current (Phase Detector) Iout - - 10 20 mA
Propagation Delay td fin = 10 kHz, VCC = 5V 10 30 50 ns
Power Dissipation PD - - 100 200 mW

Instructions for Using the CD4046B

  1. Supply Voltage:

    • Ensure the supply voltage (VCC) is within the range of 3.0V to 15.0V.
    • The typical operating voltage is 5.0V.
  2. Supply Current:

    • The quiescent current (ICC) can vary from 2.5mA to 5.0mA at 5V supply voltage.
  3. Phase Detector:

    • Connect the input signal to the phase detector input (pin 14).
    • The output voltage (Vout) will be proportional to the phase difference between the input signal and the VCO output.
    • The output current (Iout) can drive up to 20mA.
  4. VCO (Voltage-Controlled Oscillator):

    • The VCO frequency (fVCO) can be adjusted by varying the control voltage (Vctl) from 0V to VCC.
    • The VCO frequency range is typically 10kHz to 1MHz at 5V supply voltage.
    • Use external components (capacitors and resistors) to set the center frequency and range of the VCO.
  5. Propagation Delay:

    • The propagation delay (td) is the time it takes for the phase detector to respond to changes in the input signal.
    • Typical values range from 10ns to 50ns at 5V supply voltage.
  6. Power Dissipation:

    • Ensure that the power dissipation (PD) does not exceed 200mW to avoid overheating the device.
  7. Pin Configuration:

    • Refer to the datasheet for the specific pin configuration and connections.
    • Ensure all unused inputs are tied to VCC or ground to prevent floating inputs.
  8. Handling Precautions:

    • Handle the CD4046B with care to avoid static damage.
    • Use proper ESD protection when handling the device.
  9. Testing:

    • Before integrating the CD4046B into a circuit, test it on a breadboard to ensure it functions correctly.
    • Verify the VCO frequency and phase detector output using an oscilloscope.
  10. Applications:

    • The CD4046B is commonly used in PLL (Phase-Locked Loop) circuits, frequency synthesizers, and clock recovery applications.
(For reference only)

View more about CD4046B on main site