DMN6075S-7

DMN6075S-7

Category: Transistors

Specifications
SKU
11552061
Details

BUY DMN6075S-7 https://www.utsource.net/itm/p/11552061.html

Parameter Symbol Test Conditions Min Typical Max Unit
Drain-Source Voltage VDS - - - 60 V
Gate-Source Voltage VGS - - - 卤20 V
Continuous Drain Current ID TC = 25掳C - - 7.5 A
Continuous Drain Current ID TC = 70掳C - - 5.3 A
Pulse Drain Current IDM tp = 10 渭s, IG = 10 A - 40 - A
Total Power Dissipation PTOT TC = 25掳C - - 115 W
Junction Temperature TJ - - - 150 掳C
Storage Temperature Range TSTG - -65 - 150 掳C
Gate Charge QG VGS = 10 V, ID = 1 A - 22 - nC
Input Capacitance Ciss VDS = 10 V, f = 1 MHz - 1800 - pF
Output Capacitance Coss VDS = 10 V, f = 1 MHz - 120 - pF
RDS(on) at VGS = 10 V RDS(on) ID = 7.5 A, TC = 25掳C - 0.025 -
RDS(on) at VGS = 4.5 V RDS(on) ID = 7.5 A, TC = 25掳C - 0.035 -

Instructions for Use:

  1. Handling and Storage:

    • Store the DMN6075S-7 in a dry environment to prevent moisture damage.
    • Handle with care to avoid mechanical stress on the leads and body.
  2. Mounting:

    • Ensure proper thermal management by using a heat sink if necessary.
    • Soldering temperature should not exceed 260掳C for more than 10 seconds.
  3. Electrical Connections:

    • Apply gate-source voltage (VGS) within the specified range to avoid damage.
    • Ensure that the drain-source voltage (VDS) does not exceed 60V to prevent breakdown.
  4. Thermal Considerations:

    • Monitor the junction temperature (TJ) to ensure it does not exceed 150掳C.
    • Use appropriate cooling methods to maintain the device within its operational temperature range.
  5. Pulse Operation:

    • For pulse operations, ensure that the pulse duration and current do not exceed the specified limits to avoid overheating and potential failure.
  6. Testing:

    • Use the specified test conditions when measuring parameters to ensure accurate results.
    • Regularly inspect the device for signs of wear or damage.
  7. Safety:

    • Always follow safe electrical practices to avoid injury or damage to equipment.
    • Ensure that the device is properly insulated and grounded during operation.
(For reference only)