Details
BUY DMN6075S-7 https://www.utsource.net/itm/p/11552061.html
Parameter | Symbol | Test Conditions | Min | Typical | Max | Unit |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDS | - | - | - | 60 | V |
Gate-Source Voltage | VGS | - | - | - | 卤20 | V |
Continuous Drain Current | ID | TC = 25掳C | - | - | 7.5 | A |
Continuous Drain Current | ID | TC = 70掳C | - | - | 5.3 | A |
Pulse Drain Current | IDM | tp = 10 渭s, IG = 10 A | - | 40 | - | A |
Total Power Dissipation | PTOT | TC = 25掳C | - | - | 115 | W |
Junction Temperature | TJ | - | - | - | 150 | 掳C |
Storage Temperature Range | TSTG | - | -65 | - | 150 | 掳C |
Gate Charge | QG | VGS = 10 V, ID = 1 A | - | 22 | - | nC |
Input Capacitance | Ciss | VDS = 10 V, f = 1 MHz | - | 1800 | - | pF |
Output Capacitance | Coss | VDS = 10 V, f = 1 MHz | - | 120 | - | pF |
RDS(on) at VGS = 10 V | RDS(on) | ID = 7.5 A, TC = 25掳C | - | 0.025 | - | 惟 |
RDS(on) at VGS = 4.5 V | RDS(on) | ID = 7.5 A, TC = 25掳C | - | 0.035 | - | 惟 |
Instructions for Use:
Handling and Storage:
- Store the DMN6075S-7 in a dry environment to prevent moisture damage.
- Handle with care to avoid mechanical stress on the leads and body.
Mounting:
- Ensure proper thermal management by using a heat sink if necessary.
- Soldering temperature should not exceed 260掳C for more than 10 seconds.
Electrical Connections:
- Apply gate-source voltage (VGS) within the specified range to avoid damage.
- Ensure that the drain-source voltage (VDS) does not exceed 60V to prevent breakdown.
Thermal Considerations:
- Monitor the junction temperature (TJ) to ensure it does not exceed 150掳C.
- Use appropriate cooling methods to maintain the device within its operational temperature range.
Pulse Operation:
- For pulse operations, ensure that the pulse duration and current do not exceed the specified limits to avoid overheating and potential failure.
Testing:
- Use the specified test conditions when measuring parameters to ensure accurate results.
- Regularly inspect the device for signs of wear or damage.
Safety:
- Always follow safe electrical practices to avoid injury or damage to equipment.
- Ensure that the device is properly insulated and grounded during operation.
View more about DMN6075S-7 on main site