SVF18N65 18A 650V TO-220F

SVF18N65 18A 650V TO-220F

Category: Transistors

Specifications
SKU
11553319
Details

BUY SVF18N65 18A 650V TO-220F https://www.utsource.net/itm/p/11553319.html

Parameter Symbol Min Typical Max Unit Condition
Collector-Emitter Voltage VCEO - - 650 V IC = 0, Tj = 25掳C
Emitter-Collector Voltage VEBO - - 650 V IE = 0, Tj = 25掳C
Collector Current IC - 18 - A Tj = 25掳C
Continuous Collector Current IC(ON) - 18 - A Tj = 25掳C, ton = 1 ms
Pulse Collector Current IC(PULSE) - 36 - A Tj = 25掳C, tp = 10 ms, fr = 10 Hz
Gate-Emitter Voltage VGE - 卤20 - V Tj = 25掳C
Gate Threshold Voltage VGE(th) 2.0 4.0 6.0 V IC = 1 mA, Tj = 25掳C
Turn-On Delay Time td(on) - 40 70 ns VGE = 15 V, IC = 10 A, RL = 1 惟
Rise Time tr - 45 75 ns VGE = 15 V, IC = 10 A, RL = 1 惟
Turn-Off Delay Time td(off) - 40 70 ns VGE = -15 V, IC = 10 A, RL = 1 惟
Fall Time tf - 45 75 ns VGE = -15 V, IC = 10 A, RL = 1 惟
Total Switching Time tsw - 170 290 ns VGE = 15 V, IC = 10 A, RL = 1 惟
Power Dissipation PD - - 110 W TC = 25掳C
Junction Temperature Tj -170 - 150 掳C Storage and Operation
Storage Temperature Tstg -55 - 150 掳C -

Instructions for Use:

  1. Mounting and Handling:

    • Ensure proper heat sinking to maintain the junction temperature within the specified limits.
    • Handle the device with care to avoid mechanical damage.
  2. Electrical Connections:

    • Connect the collector (C), emitter (E), and gate (G) terminals correctly to avoid damage.
    • Use appropriate gate drive circuits to ensure reliable operation.
  3. Thermal Management:

    • Ensure adequate cooling to keep the junction temperature below the maximum rating.
    • Use thermal paste or thermal interface materials between the device and the heatsink for better thermal conductivity.
  4. Operating Conditions:

    • Do not exceed the maximum ratings for voltage, current, and power dissipation.
    • Operate the device within the specified temperature range to ensure reliability and longevity.
  5. Storage:

    • Store the device in a dry, cool place away from direct sunlight and sources of heat.
    • Avoid exposure to corrosive environments.
  6. Testing:

    • Use appropriate test equipment and methods to verify the device parameters.
    • Follow safety guidelines when testing high-voltage and high-current devices.
  7. Disposal:

    • Dispose of the device according to local regulations and environmental guidelines.
(For reference only)

View more about SVF18N65 18A 650V TO-220F on main site