Details
BUY K30H603 IKW30N60H3 https://www.utsource.net/itm/p/11582144.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Collector-Emitter Voltage | VCEO | - | 600 | - | V | Maximum voltage between collector and emitter with the base open. |
Collector-Base Voltage | VCBO | - | 650 | - | V | Maximum voltage between collector and base with the emitter open. |
Emitter-Base Voltage | VEBO | - | 7 | - | V | Maximum voltage between emitter and base with the collector open. |
Continuous Collector Current | IC | - | 30 | - | A | Maximum continuous current flowing from the collector to the emitter. |
Pulse Collector Current (tp = 10 ms, duty cycle = 1%) | ICM | - | 45 | - | A | Maximum pulse current flowing from the collector to the emitter. |
Power Dissipation (TC = 25°C) | PTOT | - | 240 | - | W | Maximum power dissipation at a case temperature of 25°C. |
Junction Temperature | TJ | - | - | 175 | °C | Maximum allowable junction temperature. |
Storage Temperature Range | TSTG | -55 | - | 150 | °C | Temperature range over which the device can be stored without damage. |
Forward Transconductance | gfs | - | 20 | - | S | Forward transconductance at IC = 15 A, VCE = 10 V. |
Turn-On Delay Time | td(on) | - | 0.15 | - | μs | Time from when the base-emitter voltage reaches 10% of its final value to when the collector-emitter voltage drops to 90% of its initial value. |
Rise Time | tr | - | 0.2 | - | μs | Time from when the collector-emitter voltage drops to 90% of its initial value to when it reaches 10% of its final value. |
Turn-Off Delay Time | td(off) | - | 0.2 | - | μs | Time from when the base-emitter voltage drops to 10% of its initial value to when the collector-emitter voltage rises to 10% of its final value. |
Fall Time | tf | - | 0.3 | - | μs | Time from when the collector-emitter voltage rises to 10% of its final value to when it reaches 90% of its final value. |
Instructions for Use:
Mounting and Handling:
- Ensure proper heat sinking to manage the maximum power dissipation.
- Handle the device with care to avoid mechanical stress and electrostatic discharge (ESD).
Operating Conditions:
- Do not exceed the maximum ratings specified in the table.
- Ensure that the junction temperature does not exceed 175°C to prevent thermal runaway.
Thermal Management:
- Use a suitable heat sink to maintain the device within its safe operating area (SOA).
- Consider the thermal resistance (Rth(j-c)) of the device and the heat sink to ensure effective cooling.
Electrical Connections:
- Connect the collector, emitter, and base terminals correctly.
- Use appropriate wire gauges to handle the maximum current ratings.
Testing and Measurement:
- Use a high-quality multimeter or oscilloscope to measure voltages and currents.
- Ensure that test equipment is calibrated and within its valid range.
Storage:
- Store the device in a dry, cool environment within the storage temperature range (-55°C to 150°C).
- Avoid exposure to corrosive environments and excessive humidity.
Safety Precautions:
- Follow all relevant safety standards and guidelines.
- Use appropriate personal protective equipment (PPE) when handling high-voltage circuits.