K30H603 IKW30N60H3

K30H603 IKW30N60H3

Category: Modules

Specifications
SKU
11582144
Details

BUY K30H603 IKW30N60H3 https://www.utsource.net/itm/p/11582144.html

Parameter Symbol Min Typ Max Unit Description
Collector-Emitter Voltage VCEO - 600 - V Maximum voltage between collector and emitter with the base open.
Collector-Base Voltage VCBO - 650 - V Maximum voltage between collector and base with the emitter open.
Emitter-Base Voltage VEBO - 7 - V Maximum voltage between emitter and base with the collector open.
Continuous Collector Current IC - 30 - A Maximum continuous current flowing from the collector to the emitter.
Pulse Collector Current (tp = 10 ms, duty cycle = 1%) ICM - 45 - A Maximum pulse current flowing from the collector to the emitter.
Power Dissipation (TC = 25°C) PTOT - 240 - W Maximum power dissipation at a case temperature of 25°C.
Junction Temperature TJ - - 175 °C Maximum allowable junction temperature.
Storage Temperature Range TSTG -55 - 150 °C Temperature range over which the device can be stored without damage.
Forward Transconductance gfs - 20 - S Forward transconductance at IC = 15 A, VCE = 10 V.
Turn-On Delay Time td(on) - 0.15 - μs Time from when the base-emitter voltage reaches 10% of its final value to when the collector-emitter voltage drops to 90% of its initial value.
Rise Time tr - 0.2 - μs Time from when the collector-emitter voltage drops to 90% of its initial value to when it reaches 10% of its final value.
Turn-Off Delay Time td(off) - 0.2 - μs Time from when the base-emitter voltage drops to 10% of its initial value to when the collector-emitter voltage rises to 10% of its final value.
Fall Time tf - 0.3 - μs Time from when the collector-emitter voltage rises to 10% of its final value to when it reaches 90% of its final value.

Instructions for Use:

  1. Mounting and Handling:

    • Ensure proper heat sinking to manage the maximum power dissipation.
    • Handle the device with care to avoid mechanical stress and electrostatic discharge (ESD).
  2. Operating Conditions:

    • Do not exceed the maximum ratings specified in the table.
    • Ensure that the junction temperature does not exceed 175°C to prevent thermal runaway.
  3. Thermal Management:

    • Use a suitable heat sink to maintain the device within its safe operating area (SOA).
    • Consider the thermal resistance (Rth(j-c)) of the device and the heat sink to ensure effective cooling.
  4. Electrical Connections:

    • Connect the collector, emitter, and base terminals correctly.
    • Use appropriate wire gauges to handle the maximum current ratings.
  5. Testing and Measurement:

    • Use a high-quality multimeter or oscilloscope to measure voltages and currents.
    • Ensure that test equipment is calibrated and within its valid range.
  6. Storage:

    • Store the device in a dry, cool environment within the storage temperature range (-55°C to 150°C).
    • Avoid exposure to corrosive environments and excessive humidity.
  7. Safety Precautions:

    • Follow all relevant safety standards and guidelines.
    • Use appropriate personal protective equipment (PPE) when handling high-voltage circuits.