Details
BUY MAX238CNG https://www.utsource.net/itm/p/11584499.html
IC TRANSCEIVER FULL 4/4 24DIP
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | 4.5 | 5 | 5.5 | V | Operating supply voltage |
| Input Voltage Range | VIN | -15 | +15 | V | Maximum input voltage range | |
| Output Voltage Range | VOUT | -15 | +15 | V | Maximum output voltage range | |
| Driver Output Current | IOUT | 300 | mA | Maximum output current per driver | ||
| Receiver Input Current | IIN | ±20 | mA | Maximum input current per receiver | ||
| Data Rate | fDATA | 120 | kbps | Maximum data rate | ||
| Propagation Delay | tPD | 1.5 | μs | Propagation delay from input to output | ||
| Skew | tSKEW | 0.2 | μs | Maximum skew between outputs | ||
| Power Consumption (Driver) | IDD | 0.5 | mA | Quiescent current per driver | ||
| Power Consumption (Receiver) | IDD | 0.1 | mA | Quiescent current per receiver | ||
| Operating Temperature | Toper | -40 | 85 | °C | Operating temperature range | |
| Storage Temperature | Tstg | -65 | 150 | °C | Storage temperature range |
Instructions for Use
Power Supply:
- Connect the VCC pin to a stable 5V power supply.
- Ensure the ground (GND) is properly connected to the system ground.
Signal Connections:
- Connect the RS-232 input signals (RX, TX) to the corresponding pins on the MAX238CNG.
- The driver outputs (T1, T2) should be connected to the RS-232 output lines.
- The receiver inputs (R1, R2) should be connected to the RS-232 input lines.
Decoupling Capacitors:
- Place a 0.1μF ceramic capacitor between VCC and GND as close to the device as possible to filter out noise.
Termination:
- For optimal performance, ensure that the RS-232 lines are properly terminated with a 120Ω resistor if necessary.
Data Rate:
- The MAX238CNG supports data rates up to 120 kbps. Ensure that the baud rate of your system is within this range.
Temperature Considerations:
- Operate the device within the specified temperature range (-40°C to 85°C) to avoid damage or malfunction.
Handling Precautions:
- The MAX238CNG is sensitive to electrostatic discharge (ESD). Handle the device with proper ESD precautions to prevent damage.
Storage:
- Store the device in a dry environment within the specified storage temperature range (-65°C to 150°C).
By following these guidelines, you can ensure reliable operation of the MAX238CNG in your application.
(For reference only)View more about MAX238CNG on main site