DS26LS32CM

DS26LS32CM


Specifications
SKU
11627152
Details

BUY DS26LS32CM https://www.utsource.net/itm/p/11627152.html
IC RECEIVER 0/4 16SOIC
Parameter Symbol Min Typical Max Unit Notes
Supply Voltage VCC 4.75 5.0 5.25 V
Output High Voltage VOH 2.4 3.5 5.0 V @ IOL = -4mA, VCC = 5V
Output Low Voltage VOL 0 0.4 0.5 V @ IOH = 4mA, VCC = 5V
Input High Voltage VIH 2.0 5.0 V
Input Low Voltage VIL 0 0.8 V
Propagation Delay Time tpd 11 22 ns @ VCC = 5V, TA = 25°C
Power Dissipation PD 125 mW @ VCC = 5V, f = 10MHz
Operating Temperature TA -40 85 °C
Storage Temperature Tstg -65 150 °C

Instructions for Use

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 4.75V to 5.25V.
    • Connect the ground (GND) pin to a stable reference ground.
  2. Input Signals:

    • Input signals should be within the specified input voltage levels (VIL and VIH).
    • Avoid applying voltages outside the VCC and GND range to prevent damage.
  3. Output Signals:

    • The output high (VOH) and low (VOL) voltages are specified for typical operating conditions.
    • Ensure that the load connected to the output does not exceed the maximum current ratings.
  4. Propagation Delay:

    • The propagation delay time (tpd) is critical for timing considerations in digital circuits.
    • Use the typical value for design calculations and ensure the maximum value is accounted for in worst-case scenarios.
  5. Temperature Considerations:

    • Operate the device within the specified operating temperature range (-40°C to 85°C).
    • Store the device within the storage temperature range (-65°C to 150°C).
  6. Handling:

    • Handle the device with care to avoid static discharge, which can damage sensitive components.
    • Follow proper ESD (Electrostatic Discharge) handling procedures.
  7. Mounting:

    • Ensure proper mounting and soldering techniques to maintain electrical and mechanical integrity.
    • Use appropriate thermal management techniques if operating at high power or in high-temperature environments.
  8. Testing:

    • Test the device under controlled conditions to verify its performance before integrating it into a larger system.
    • Use the specified test conditions (e.g., VCC = 5V, TA = 25°C) for accurate measurements.
(For reference only)