Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VDD - 1.65 - 3.6 V
Quiescent Current IQ All switches off, VDD = 2.5V - 0.8 - 渭A
On-State Resistance RON VDD = 2.5V, VIN = 0V to VDD 4 - 7
Off-State Leakage Current IOFF VDD = 2.5V, VIN = 0V to VDD - 1 - nA
Input Signal Range VIN - 0 - VDD V
Switching Time (On) tON VDD = 2.5V, VIN = 0V to VDD - 0.5 - 渭s
Switching Time (Off) tOFF VDD = 2.5V, VIN = 0V to VDD - 0.5 - 渭s
Operating Temperature TOP - -40 - 85 掳C
Storage Temperature TSTG - -65 - 150 掳C

Instructions for Use:

  1. Power Supply:

    • Ensure that the supply voltage (VDD) is within the range of 1.65V to 3.6V.
    • Connect the VDD pin to the power supply and GND to ground.
  2. Signal Connections:

    • Connect the input signals to the appropriate channels (IN1, IN2, IN3).
    • Connect the output signals to the common output (OUT).
  3. Control Signals:

    • Use the control inputs (S0, S1, S2) to select the desired channel. The control signals should be logic levels compatible with the supply voltage.
    • The truth table for the control inputs is as follows:
      • S2 S1 S0 | Channel
      • 0 0 0 | OFF
      • 0 0 1 | IN1
      • 0 1 0 | IN2
      • 0 1 1 | IN3
  4. Quiescent Current:

    • The quiescent current (IQ) is typically 0.8 渭A when all switches are off. This should be considered in low-power applications.
  5. On-State Resistance:

    • The on-state resistance (RON) is between 4 惟 and 7 惟 at VDD = 2.5V. This affects the signal integrity and power consumption when the switch is on.
  6. Off-State Leakage Current:

    • The off-state leakage current (IOFF) is typically 1 nA. This is important for applications where minimal leakage is required.
  7. Switching Times:

    • The switching times (tON and tOFF) are both typically 0.5 渭s. This is useful for high-speed switching applications.
  8. Temperature Considerations:

    • The operating temperature range is from -40掳C to 85掳C.
    • The storage temperature range is from -65掳C to 150掳C.
  9. Handling and Storage:

    • Store the device in a dry environment to prevent moisture damage.
    • Handle the device with care to avoid static discharge, which can damage the internal components.
  10. Testing:

    • Before integrating the device into a circuit, test it with a simple setup to ensure proper functionality.
    • Use a multimeter to check the continuity and resistance values when the switch is on and off.
(For reference only)