Details
BUY AN16524A https://www.utsource.net/itm/p/11654261.html
Parameter | Description | Value | Unit |
---|---|---|---|
Device Type | High-side Switch with Diagnostic Functions | - | - |
Supply Voltage (VIN) | Operating Range | 4.5 to 30 | V |
Continuous Load Current (IL) | Maximum | 1.2 | A |
Peak Load Current (IL,peak) | Maximum | 2.0 | A |
On-State Resistance (RDS(on)) | Typical at 12V, 25掳C | 0.35 | 惟 |
Diagnostics | Open Load Detection | Yes | - |
Short-to-Ground Detection | Yes | - | |
Over-Temperature Protection | Yes | - | |
Thermal Shutdown Temperature | Typical | 165 | 掳C |
Operating Temperature Range | Ambient | -40 to 125 | 掳C |
Package Type | SOT23-5L | - | - |
Instructions for AN16524A
Power Supply Connection:
- Connect the supply voltage (VIN) to the VIN pin.
- Ensure the supply voltage is within the operating range of 4.5V to 30V.
Load Connection:
- Connect the load between the OUT pin and ground.
- The continuous load current should not exceed 1.2A, and the peak load current should not exceed 2.0A.
Control Signal:
- Apply a logic high signal to the IN pin to turn on the switch.
- Apply a logic low signal to the IN pin to turn off the switch.
Diagnostics:
- Monitor the DIAG pin for diagnostic information.
- The DIAG pin will indicate open load, short-to-ground, or over-temperature conditions.
Thermal Management:
- Ensure adequate heat dissipation to prevent the device from exceeding the thermal shutdown temperature of 165掳C.
- Use a heatsink if necessary, especially for high current applications.
Operating Environment:
- Operate the device within the ambient temperature range of -40掳C to 125掳C.
Handling:
- Handle the device with care to avoid damage to the pins and internal components.
- Follow ESD (Electrostatic Discharge) precautions to prevent damage.
Testing:
- Test the device under typical operating conditions to ensure proper functionality.
- Verify the on-state resistance and diagnostic outputs during testing.
View more about AN16524A on main site