Details
BUY BT145-800R https://www.utsource.net/itm/p/11654812.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Rated Off-State Voltage | VDRM | - | 800 | - | V | Maximum voltage the device can withstand when off |
Rated On-State Current | ITSM | - | 8 | - | A | Maximum current through the device when on |
Gate Trigger Current | IGT | 10 | - | 20 | mA | Minimum current required to turn the device on |
Holding Current | IH | 5 | - | 10 | mA | Minimum current required to keep the device on |
On-State Voltage Drop | VTM | - | 1.3 | - | V | Voltage drop across the device when on |
Turn-On Time | ton | - | 0.5 | 1 | 渭s | Time taken for the device to turn on |
Turn-Off Time | toff | - | 1.5 | 3 | 渭s | Time taken for the device to turn off |
Power Dissipation | PD | - | - | 10 | W | Maximum power dissipation at rated conditions |
Operating Temperature | TJ | -65 | - | 125 | 掳C | Junction temperature range |
Storage Temperature | TSTG | -65 | - | 150 | 掳C | Temperature range for storage |
Instructions:
Handling and Storage:
- Store the device in a dry, cool place.
- Avoid exposure to high temperatures and humidity.
- Handle with care to prevent damage to the leads and body.
Mounting:
- Ensure proper heat sinking if operating near maximum power dissipation.
- Use appropriate mounting hardware to secure the device.
Operation:
- Ensure the gate trigger current (IGT) is sufficient to turn the device on.
- Maintain the holding current (IH) to keep the device in the on state.
- Do not exceed the rated off-state voltage (VDRM) or on-state current (ITSM).
Testing:
- Use a suitable test setup to measure the parameters.
- Ensure the test environment is controlled to avoid external interference.
Safety:
- Follow all safety guidelines when handling high-voltage components.
- Use appropriate protective equipment and grounding techniques.
For more detailed information, refer to the datasheet provided by the manufacturer.
(For reference only)View more about BT145-800R on main site