CS5509-AS

CS5509-AS


Specifications
SKU
11655146
Details

BUY CS5509-AS https://www.utsource.net/itm/p/11655146.html

Parameter Description Value/Range
Device High Performance 16-bit Analog-to-Digital Converter (ADC) with I2C Interface CS5509-AS
Supply Voltage (VDD) Operating Supply Voltage 2.7 V to 5.25 V
I2C Interface Communication Protocol Standard and Fast Mode
Resolution ADC Resolution 16 bits
Conversion Time Time to Complete a Conversion 33 ms (Max)
Input Range Analog Input Voltage Range 0 V to VDD
Power Consumption Typical Power Consumption 300 渭A (Active), 1 渭A (Shutdown)
Temperature Range Operating Temperature Range -40掳C to +85掳C
Package Package Type SOIC-8

Instructions for Use

  1. Power Supply:

    • Connect the VDD pin to a power supply within the range of 2.7 V to 5.25 V.
    • Connect the GND pin to the ground.
  2. I2C Configuration:

    • Connect the SDA (Data) and SCL (Clock) pins to the I2C bus.
    • Ensure pull-up resistors are connected to both SDA and SCL lines to VDD.
  3. Initialization:

    • Send a start condition followed by the device address (0x90 for write, 0x91 for read).
    • Write the configuration register to set the desired mode (e.g., single conversion, continuous conversion).
  4. Conversion:

    • To start a conversion, write to the control register.
    • For single conversion mode, the device will perform one conversion and then enter idle mode.
    • For continuous conversion mode, the device will continuously perform conversions.
  5. Reading Data:

    • After the conversion is complete, send a start condition followed by the device address for read.
    • Read the data from the data register (16-bit value).
  6. Shutdown Mode:

    • To reduce power consumption, write to the control register to enter shutdown mode.
    • The device will consume approximately 1 渭A in this mode.
  7. Temperature Considerations:

    • Ensure the operating temperature is within the specified range (-40掳C to +85掳C).
  8. Handling Static Electricity:

    • Handle the device with care to avoid damage from static electricity.
  9. Decoupling Capacitors:

    • Place decoupling capacitors close to the VDD and GND pins to ensure stable operation. Typically, a 0.1 渭F capacitor is recommended.
(For reference only)

View more about CS5509-AS on main site