Details
BUY MCP3204-BI/P https://www.utsource.net/itm/p/11657709.html
| Parameter | Description | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Resolution | Number of bits | - | 12 | - | Bits |
| Conversion Time | Time to convert one sample | - | 25 | - | 渭s |
| Input Voltage Range | Range of input voltages | 0 | - | VREF | V |
| Reference Voltage (VREF) | External reference voltage range | 2.7 | - | 5.5 | V |
| Supply Voltage (VDD) | Operating supply voltage range | 2.7 | - | 5.5 | V |
| Supply Current | Typical current consumption | - | 250 | - | 渭A |
| Differential Nonlinearity Error (DNL) | Maximum deviation from ideal step size | -1 | - | +1 | LSB |
| Integral Nonlinearity Error (INL) | Maximum deviation from ideal transfer function | -4 | - | +4 | LSB |
| Power-down Mode | Current consumption in power-down mode | - | 0.5 | - | 渭A |
| Operating Temperature Range | Temperature range for normal operation | -40 | - | 85 | 掳C |
| Package | Type of package | - | - | - | BI/P (PDIP-16) |
Instructions for Using MCP3204-BI/P
Power Supply:
- Connect the VDD pin to a stable power supply within the range of 2.7V to 5.5V.
- Connect the VSS pin to ground.
Reference Voltage:
- Connect the VREF pin to a stable reference voltage within the range of 2.7V to 5.5V. If not used, connect it to VDD for a full-scale input range.
Analog Inputs:
- Connect the analog signals to be measured to the AN0, AN1, AN2, and AN3 pins. Ensure the input voltage is within the range of 0V to VREF.
Digital Interface:
- Connect the CS (Chip Select), SCK (Serial Clock), DIN (Data In), and DOUT (Data Out) pins to your microcontroller or digital interface.
- Set CS low to initiate communication.
- Use the SCK line to clock data into and out of the ADC.
- Data is shifted out on the rising edge of SCK and sampled on the falling edge.
Conversion Start:
- Send a start conversion command by setting CS low and sending the appropriate control word via DIN.
- The control word specifies the channel to be converted and the mode of operation (single-ended or differential).
Data Read:
- After the conversion is complete, the data can be read from the DOUT pin.
- The conversion result is 12 bits long and is transmitted in MSB-first format.
Power-down Mode:
- To enter power-down mode, set CS high and keep it high until the next conversion is needed.
- This reduces power consumption to approximately 0.5 渭A.
Temperature Considerations:
- Ensure the operating temperature is within the specified range of -40掳C to 85掳C to maintain accuracy and reliability.
Handling and Storage:
- Handle the device with care to avoid static damage.
- Store in a dry, cool place away from direct sunlight and sources of heat.
View more about MCP3204-BI/P on main site