| Parameter | Description | Min | Typ | Max | Unit |
|---|---|---|---|---|---|
| Supply Voltage (VDD) | Operating supply voltage | 2.7 | - | 5.5 | V |
| Output Power | Maximum output power at 1.8V supply | - | 10 | - | dBm |
| Current Consumption | Current consumption at 1.8V supply and 10dBm output power | - | 13.5 | - | mA |
| Standby Current | Current consumption in standby mode | - | 0.1 | - | 渭A |
| Operating Temperature | Range of operating temperatures | -40 | - | 85 | 掳C |
| Storage Temperature | Range of storage temperatures | -55 | - | 125 | 掳C |
| RF Input Impedance | Input impedance at RF pin | - | 50 | - | 惟 |
| RF Output Impedance | Output impedance at RF pin | - | 50 | - | 惟 |
| Modulation Schemes | Supported modulation schemes | - | GFSK, FSK, MSK, ASK, OOK, 2-FSK, 4-FSK | - | - |
| Data Rate | Maximum data rate | - | 200 | - | kbps |
| Frequency Range | Operating frequency range | 240 | - | 960 | MHz |
Instructions for Using RDA1846
Power Supply:
- Connect the VDD pin to a power supply within the range of 2.7V to 5.5V.
- Ensure a stable power supply to avoid performance degradation.
Ground Connection:
- Connect the GND pin to a common ground to ensure proper operation.
RF Input/Output:
- Connect the RF input/output pins to a 50惟 impedance matching network.
- Use appropriate filters and matching circuits to optimize performance.
Modulation and Data Rate:
- Configure the modulation scheme and data rate according to your application requirements.
- Refer to the datasheet for specific configuration details.
Temperature Considerations:
- Operate the device within the temperature range of -40掳C to 85掳C for optimal performance.
- Store the device in an environment with temperatures between -55掳C and 125掳C.
Standby Mode:
- To reduce power consumption, use the standby mode by setting the appropriate control signals.
- The current consumption in standby mode is approximately 0.1渭A.
Testing and Troubleshooting:
- Use a spectrum analyzer to verify the output power and frequency stability.
- Check for any interference or noise that might affect performance.
Schematic and Layout Guidelines:
- Follow the recommended PCB layout guidelines to minimize parasitic effects and improve signal integrity.
- Place decoupling capacitors close to the VDD and GND pins to filter out noise.
Regulatory Compliance:
- Ensure that the design complies with relevant regulatory standards for radio frequency emissions and immunity.
For more detailed information, refer to the RDA1846 datasheet and application notes provided by the manufacturer.