S29GL032N90TFI040

S29GL032N90TFI040


Specifications
SKU
11659425
Details

BUY S29GL032N90TFI040 https://www.utsource.net/itm/p/11659425.html

Parameter Description Value Unit
Device Type Non-Volatile Memory 32 Mbit Serial Flash -
Package Package Type 8-Pin TSSOP -
Operating Voltage (Vcc) Supply Voltage Range 2.7 to 3.6 V
Standby Current (Typical) Power Consumption in Standby Mode 5 渭A
Active Current (Typical) Power Consumption in Active Mode 3 mA
Programming Time (Typical) Time to Program a Page 2 ms
Erase Time (Typical) Time to Erase a Sector 30 ms
Data Retention Minimum Data Retention Time 20 years
Endurance Number of Write/Erase Cycles 100,000 cycles
Operating Temperature Temperature Range for Operation -40 to +85 掳C
Storage Temperature Temperature Range for Storage -65 to +150 掳C
Organization Memory Organization 4,194,304 x 8 bits
Interface Communication Protocol SPI (Serial Peripheral Interface) -
Command Set Command Set Compatibility JEDEC Standard -

Instructions:

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the range of 2.7V to 3.6V.
    • Connect the Vcc pin to the power supply and the GND pin to ground.
  2. Communication:

    • Use the SPI interface to communicate with the device.
    • Connect the following pins:
      • CS (Chip Select): Active low.
      • SCK (Serial Clock): Input clock signal.
      • SI (Serial Input): Data input.
      • SO (Serial Output): Data output.
  3. Initialization:

    • Before performing any read or write operations, ensure the device is properly initialized by setting the CS pin low.
    • After initialization, set the CS pin high to end the command sequence.
  4. Read Operations:

    • To read data, send the Read command (0x03) followed by the address of the memory location.
    • The device will then output the data from the specified address.
  5. Write Operations:

    • To write data, first send the Write Enable command (0x06).
    • Then, send the Write command (0x02) followed by the address and the data to be written.
    • Wait for the Write In Progress (WIP) bit in the Status Register to clear before initiating another write operation.
  6. Erase Operations:

    • To erase a sector, first send the Write Enable command (0x06).
    • Then, send the Sector Erase command (0xD8) followed by the address of the sector to be erased.
    • Wait for the WIP bit to clear before performing any other operations.
  7. Status Register:

    • The status register can be read using the Read Status Register command (0x05).
    • The WIP bit indicates whether a write or erase operation is in progress.
  8. Data Retention and Endurance:

    • Ensure that the device is stored and operated within the specified temperature ranges to maintain data retention and endurance.
  9. Handling:

    • Handle the device with care to avoid damage from electrostatic discharge (ESD).

For more detailed information, refer to the datasheet provided by the manufacturer.

(For reference only)

View more about S29GL032N90TFI040 on main site