Parameter Symbol Min Typ Max Unit Conditions
Forward Voltage VF - 1.2 1.6 V IF = 10 mA
Forward Current IF - - 30 mA Continuous
Peak Forward Current IFP - - 100 mA tP = 1 ms, Repetition Rate = 100 Hz
Reverse Voltage VR - - 5 V
Output Collector-Emitter Voltage VCEO - - 30 V IC = 100 mA
Output Collector Current IC - - 100 mA VCEO = 30 V
Output Turn-On Time tON - 1 5 渭s IF = 10 mA, RL = 100 惟
Output Turn-Off Time tOFF - 1 5 渭s IF = 10 mA, RL = 100 惟
Isolation Voltage VIORM - - 2500 Vrms Test Condition: 1 min
Operating Temperature TOPR -40 - 105 掳C
Storage Temperature TSTG -55 - 125 掳C

Instructions for Use:

  1. Forward Current (IF):

    • Ensure that the forward current does not exceed 30 mA continuously.
    • For peak applications, do not exceed 100 mA with a pulse width of 1 ms and a repetition rate of 100 Hz.
  2. Reverse Voltage (VR):

    • The reverse voltage should not exceed 5 V to avoid damage to the device.
  3. Output Collector-Emitter Voltage (VCEO):

    • Ensure that the collector-emitter voltage does not exceed 30 V when the collector current is 100 mA.
  4. Output Collector Current (IC):

    • The maximum collector current should not exceed 100 mA at a collector-emitter voltage of 30 V.
  5. Output Turn-On and Turn-Off Times:

    • The typical turn-on and turn-off times are 1 渭s, but they can vary up to 5 渭s. Ensure that your circuit design accounts for these times to avoid transient issues.
  6. Isolation Voltage (VIORM):

    • The isolation voltage is 2500 Vrms, tested for 1 minute. Ensure that the input and output circuits are properly isolated to maintain this rating.
  7. Operating and Storage Temperature:

    • The operating temperature range is from -40掳C to 105掳C.
    • The storage temperature range is from -55掳C to 125掳C.
  8. Handling Precautions:

    • Handle the TLP596G with care to avoid static discharge and physical damage.
    • Ensure proper heat sinking if the device is expected to dissipate significant power.
  9. Mounting:

    • Follow recommended PCB layout guidelines to ensure optimal performance and thermal management.
    • Use appropriate soldering techniques to avoid overheating the device during assembly.