Details
BUY G20N60 https://www.utsource.net/itm/p/11682433.html
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Collector-Emitter Voltage | VCE | - | - | 600 | V | Maximum voltage between collector and emitter with the base open. |
Emitter-Collector Voltage | VEC | - | - | 600 | V | Maximum voltage between emitter and collector with the base open. |
Base-Emitter Voltage | VBE | - | 2.5 | 3.0 | V | Maximum voltage between base and emitter. |
Collector Current | IC | - | - | 20 | A | Maximum continuous collector current. |
Power Dissipation | PT | - | - | 180 | W | Maximum power dissipation at TC = 25°C. |
Junction Temperature | TJ | - | - | 150 | °C | Maximum junction temperature. |
Storage Temperature | TSTG | -40 | - | 150 | °C | Operating temperature range for storage. |
Transition Frequency | fT | - | 75 | - | kHz | Frequency at which hfe is reduced to 1. |
Continuous Gate Charge | QG | - | 100 | - | nC | Total gate charge. |
Turn-On Time | ton | - | 0.5 | - | μs | Time required for the transistor to turn on. |
Turn-Off Time | toff | - | 1.5 | - | μs | Time required for the transistor to turn off. |
Instructions:
Mounting and Handling:
- Ensure that the device is handled with care to avoid mechanical damage.
- Use appropriate heat sinks to manage the thermal resistance and ensure proper heat dissipation.
Electrical Connections:
- Connect the collector (C), emitter (E), and base (B) terminals correctly to avoid damage.
- Ensure that the maximum ratings for voltage, current, and power dissipation are not exceeded.
Operating Conditions:
- Operate the device within the specified temperature range to prevent thermal runaway.
- Use derating factors for power dissipation if operating at temperatures above 25°C.
Storage:
- Store the device in a dry, cool place to prevent moisture damage.
- Avoid exposure to extreme temperatures or corrosive environments.
Testing:
- Use a multimeter or appropriate testing equipment to verify the device parameters before installation.
- Follow safety guidelines to prevent electrical shock or damage to the device.
Application:
- The G20N60 is suitable for high-power switching applications, motor control, and other industrial electronics where high current and voltage handling is required.
View more about G20N60 on main site